beautypg.com

Accusys ExaRAID GUI User Manual

Page 359

background image

Appendix

D-70

Event ID

0x2438

Type

SYSTEM

Severity

INFO

Parameters

Message

Enclosure serial number in controller x updated by controller y

Description

During fail-back, if enclosure serial number of returning controller
x is not the same as controller y. The enclosure serial number of
controller x will be updated by controller y automatically

Advice

None

Event ID

0x2439

Type

SYSTEM

Severity

ERROR

Parameters

Message

RCC link or protocol not correct

Description

The internal link or transfer protocol of the returning controller
doesn’t work well

Advice

Contact local sales or support office

Event ID

0x243a

Type

SYSTEM

Severity

WARNING

Parameters

Message

The model name of the returning controller is not the same

Description

The model name of the returning controller is not the same

Advice

Make sure the model name of the returning controller is the
same. If not the same, replace the returning controller board.

Event ID

0x243b

Type

SYSTEM

Severity

WARNING

Parameters

Message

The Daughter board model of the returning controller is not the
same

Description

The Daughter board model of the returning controller is not the
same

Advice

Make sure the daughter board moduel of the returning controller
is the same. If not the same, replace the daughter boadr module
of the returning controller to make the models are the same.

Event ID

0x243c

Type

CONTROLLER

Severity

WARNING

Parameters

Message

The Memory size of the returning controller is not the same

Description

The Memory size of the returning controller is not the same

Advice

Make sure the memory size of the returning controller is the same.
If not the same, replace the memory module of the returning
controller to make the memory size are the same.