beautypg.com

Accusys ExaRAID GUI User Manual

Page 358

background image

Appendix

D-69

• Fail-back

Event ID

0x2451

Type

SYSTEM

Severity

WARNING

Parameters

Message

Enclosure serial number are not the same

Description

Enclosure serial number are not the same, only one controller will
be startup

Advice

Check Enclosure serial number of both controller, and update
the wanted serial number to another controller

Event ID

0x2829

Type

SYSTEM

Severity

WARNING

Parameters

Message

BBM optional are not the same

Description

BBM optional are not the same, only one controller will be startup

Advice

Check BBM option of both controller, and apply the wanted
option to another controller

Event ID

0x2435

Type

SYSTEM

Severity

INFO

Parameters

Controller
ID, Control-
ler ID

Message

Boot code in controller x updated by controller y

Description

During fail-back, if the boot cade version of returning controller x
is not the same as controller y. The boot code of controller x will
be updated by controller y automatically.

Advice

None

Event ID

0x2436

Type

SYSTEM

Severity

INFO

Parameters

Controller
ID, Control-
ler ID

Message

System firmware in controller x updated by controller y

Description

During fail-back, if the system firmware version of returning con-
troller x is not the same as controller y. The system firmware of
controller x will be update by controller y automatically

Advice