Accusys ExaRAID GUI User Manual
Page 317

Appendix
D-28
• Disk port and chip
Event ID
0x081e
Type
DISK
Severity
NOTICE
Parameters
DISK ID, 
opcode, 
sense key, 
ASC, ASCQ
Message
Check condition on HDDv: SCSI opcode=w, Sense Key=x, ASC=y, 
ASCQ=z
Description
This presents the SCSI status number when error happens such as 
CRC error and it will have some field (Sense Key, ASC, ASCQ).
Advice
If this event occurs often, check the disk connectivity, check 
power supply to disks, or replace with a new disk.
Event ID
0x0813
Type
DISK
Severity
NOTICE
Parameters
Controller 
ID, DISK ID, 
Error Code
Message
Controller x detected gross error on HDDy with code z
Description
The controller x makes gross error on hddy, with parameter code 
z. This could be transient error due to unstable channel, elec-
tronic interference, heavy traffic, casually misbehaved hard 
disks, or old FW. The controller will invalidate the data and retry 
the command.
Advice
If this event occurs often, check the disk connectivity, check 
power supply to disks, replace with a new disk, or contact local 
sales or support office.
Event ID
0x081b
Type
DISK
Severity
ERROR
Parameters
Disk port ID, 
Controller ID
Message
Reset disk port x in controller y
Description
The controller y resets disk port x that failed to execute com-
mands properly. This could be a transient error due to unstable 
channel, heavy traffic, or malfunctioning hard disks. The control-
ler will resume normal operations after reset; however, this could 
result in performance drop of the disks attached to the disk port.
Advice
If this event occurs often, check the disk connectivity, check 
power supply to disks, or replace with a new disk.