D-28

• Disk port and chip

Event ID

0x081e

Type

DISK

Severity

NOTICE

Parameters

DISK ID,
opcode,
sense key,
ASC, ASCQ

Message

Check condition on HDDv: SCSI opcode=w, Sense Key=x, ASC=y,
ASCQ=z

Description

This presents the SCSI status number when error happens such as
CRC error and it will have some field (Sense Key, ASC, ASCQ).

Advice

If this event occurs often, check the disk connectivity, check
power supply to disks, or replace with a new disk.

Event ID

0x0813

Type

DISK

Severity

NOTICE

Parameters

Controller
ID, DISK ID,
Error Code

Message

Controller x detected gross error on HDDy with code z

Description

The controller x makes gross error on hddy, with parameter code
z. This could be transient error due to unstable channel, elec-
tronic interference, heavy traffic, casually misbehaved hard
disks, or old FW. The controller will invalidate the data and retry
the command.

Advice

If this event occurs often, check the disk connectivity, check
power supply to disks, replace with a new disk, or contact local
sales or support office.

Event ID

0x081b

Type

DISK

Severity

ERROR

Parameters

Disk port ID,
Controller ID

Message

Reset disk port x in controller y

Description

The controller y resets disk port x that failed to execute com-
mands properly. This could be a transient error due to unstable
channel, heavy traffic, or malfunctioning hard disks. The control-
ler will resume normal operations after reset; however, this could
result in performance drop of the disks attached to the disk port.

Advice

If this event occurs often, check the disk connectivity, check
power supply to disks, or replace with a new disk.