Accusys ExaRAID GUI User Manual
Page 205

Advanced Functions
5-32
Normally, the heartbeat LED on each controller board is flashing 
periodically and the system keeps syncing state messages shown on the 
GUI to identify the controller is alive. When a heartbeat LED does not flash 
anymore, or the state message cannot be synced, the controller will be 
regarded as failed.
Controller Failback
If a system is in the controller failover mode, the survival controller will take 
over the failed controller’s job and process its own job. When a healthy 
replacement controller is installed, the system will proceed the failback 
process. The survival controller will return the failed controller’s job and 
sync all states and configuration to the failback controller.
When the redundant mode is established, the heartbeat LED of the 
failback controller flashes. Never remove or power down (through the 
GUI) the survival controller before the failback controller heartbeat LED 
starts flashing.
•
GUI Notification
When one of the controller is failover, the following notification message 
will be displayed and provide the link to the backup controller. Click ‘Go 
to peer controller’s GUI’ to view or configure settings.
When a controller is failback, a pop-up dialog box appears to notify users 
that the system is doing failback (GUI screen is polling every 15 seconds). 
Users can click the OK button when the failback process is finished.
Note
When the heartbeat LED of both controllers are flashing, users are 
allowed to hot remove any one controller.
Note
1. Only the tasks belong to the preferred controller will be returned
to the failback controller. If you have changed the preferred 
controller for tasks to the survival controller, the survival controller 
then takes the ownership of those tasks. For more information 
about preferred controller, see Owner controller and preferred 
controller on page 5-20.
2. The replacement must be exactly the same controller as the
surviving one, as mentioned previously.
Figure 5-13 Controller failover and the page redirection message