beautypg.com

Accusys ExaRAID GUI User Manual

Page 295

background image

Appendix

D-6

• Roaming

• Recovery

Event ID

0x2063

Type

RAID

Severity

NOTICE

Parameters

Rebuild
progress,
DG ID,
Notify
threshold

Message

Rebuild progress(y%) on DGx reach to the notify percent(z%)

Description

The progress of rebuilding has reached the pre-define threshold.

Advice

None

Event ID

0x0820

Type

RAID

Severity

INFO

Parameters

Message

Disks changed during power-off

Description

The number of disks installed is different when the controller was
powered off. Either existing disks were removed or new disks were
installed during power-off.

Advice

Check hard disk status, and conduct roaming or recovery, if nec-
essary.

Event ID

0x1004

Type

RAID

Severity

INFO

Parameters

DG ID

Message

DGx is imported

Description

Foreign disk group has been imported to be dgx.

Advice

None

Event ID

0x1c02

Type

RAID

Severity

INFO

Parameters

VOL ID

Message

VOLx is imported

Description

Foreign volume has been imported to be volx.

Advice

None

Event ID

0x2052

Type

RAID

Severity

INFO

Parameters

DG ID

Message

DGx is recovered

Description

Disk group dgx has been recovered.

Advice

None