• Power supply

Event ID

0x2821

Type

ENCLOSURE

Severity

NOTICE

Parameters

Voltage,
Enclosure ID

Message

Voltage source x in enclosure y back to normal

Description

Voltage source x in enclosure y returned to normal range.

Advice

If the voltage is very unstable, contact local sales or support
office.

Event ID

0x2822

Type

ENCLOSURE

Severity

WARNING

Parameters

Voltage ID,
Enclosure ID,
Voltage

Message

Abnormal voltage source x in enclosure y (z V)

Description

Voltage source x in enclosure y was out of normal range.

Advice

Check the power supply system, or contact local sales or support
office.

Event ID

0x280d

Type

ENCLOSURE

Severity

INFO

Parameters

PSU ID,
Enclosure ID

Message

Power supply x in enclosure y detected

Description

Power supply unit (PSU) x was installed and present.

Advice

None

Event ID

0x280e

Type

ENCLOSURE

Severity

ERROR

Parameters

PSU ID,
Enclosure ID

Message

Power supply x in enclosure y failed

Description

The controller cannot get status from power supply unit (PSU) x in
enclosure y, which might have failed or removal.

Advice

Replace the power supply, or contact local sales or support
office.