beautypg.com

Accusys ExaRAID GUI User Manual

Page 305

background image

Appendix

D-16

Event ID

0x2048

Type

TASK

Severity

WARNING

Parameters

DISK ID,
DISK ID

Message

Clone from HDDx to HDDy failed to auto start

Description

Auto disk cloning from hddx to hddy failed to start.

Advice

Check if the disk failed or the source disk group is non-optimal
when starting the task.

Event ID

0x2018

Type

TASK

Severity

NOTICE

Parameters

DISK ID,
DISK ID

Message

Clone from HDDx to HDDy paused

Description

Disk cloning from hddx to hddy was paused.

Advice

Check if the source disk group is busy or non-optimal during the
task.

Event ID

0x2019

Type

TASK

Severity

NOTICE

Parameters

DISK ID,
DISK ID

Message

Clone from HDDx to HDDy resumed

Description

Disk cloning from hddx to hddy was resumed.

Advice

None

Event ID

0x2017

Type

TASK

Severity

INFO

Parameters

DISK ID,
DISK ID

Message

Clone from HDDx to HDDy stopped

Description

Disk cloning from hddx to hddy was stopped manually.

Advice

None

Event ID

0x201a

Type

TASK

Severity

WARNING

Parameters

DISK ID,
DISK ID

Message

Clone from HDDx to HDDy aborted

Description

Clone from hddx to hddy was aborted.

Advice

Check if the disk failed or the target disk was rebuilding when the
source disk failed.