beautypg.com

Accusys ExaRAID GUI User Manual

Page 356

background image

Appendix

D-67

• Email (SMTP) server status

• System start-up and shutdown

Event ID

0x2450

Type

SYSTEM

Severity

WARNING

Parameters

Message

Firmware version are not the same

Description

Firmware version are not the same, only one controller will be
startup

Advice

Check firmware version of both controller, and update the
wanted firmware to another controller

Event ID

0x240b

Type

SYSTEM

Severity

WARNING

Parameters

Message

Controller x failed to send mail

Description

The controller failed to send mail. Both primary and secondary
mail servers cannot be reached by the controller.

Advice

Check if the network connection is up, and check if the network
and SMTP settings are correct.

Event ID

0x240a

Type

SYSTEM

Severity

INFO

Parameters

Message

Controller x sned mail back to normal

Description

The controller can reach the mail server and start to send mail.

Advice

None

Event ID

0x2402

Type

SYSTEM

Severity

INFO

Parameters

Message

System to be restarted or halted

Description

The RAID system is going to get restarted or halted.

Advice

None

Event ID

0x2403

Type

SYSTEM

Severity

INFO

Parameters

Message

RAID system started

Description

The RAID system was started.

Advice

None