beautypg.com

Accusys ExaRAID GUI User Manual

Page 350

background image

Appendix

D-61

Event ID

0x2401

Type

SYSTEM

Severity

INFO

Parameters

Message

RAID configurations on all disks erased

Description

RAID configurations stored on all disks were erased. All RAID con-
figurations are lost.

Advice

Restart the controller so that all disks can be re-initialized all
together.

Event ID

0x2415

Type

SYSTEM

Severity

INFO

Parameters

Message

NVRAM configurations restore to default

Description

The controller configurations stored on NVRAM were erased and
restored to factory default.

Advice

None

Event ID

0x2416

Type

SYSTEM

Severity

INFO

Parameters

DISK ID

Message

NVRAM configurations restored from HDDx

Description

The NVRAM configurations were restored from hddx.

Advice

None

Event ID

0x2417

Type

SYSTEM

Severity

INFO

Parameters

Message

NVRAM configurations restored from file

Description

The configurations were restored from a file uploaded to the
controller.

Advice

None

Event ID

0x2409

Type

SYSTEM

Severity

FATAL

Parameters

Message

NVRAM configuration checksum error

Description

The checksum stored on NVRAM do not match the contents on
NVRAM. This could happen if the controller was not properly shut-
down. Because NVRAM configurations might be corrupt and
cannot be trusted, all event logs are automatically erased.

Advice

Restore the configurations from hard disks or by uploading the
backed-up configuration file. If this event happens continuously,
contact local sales or support office.