D-36

• Disk Cache

Event ID

0x1405

Type

DISK

Severity

WARNING

Parameters

Disk ID

Message

Primary BBR table on HDDx is corrupt

Description

The controller failed to access the primary BBR table on hddx
and the table was invalid. However, the secondary BBR table still
works.

Advice

Start to monitor the status of the secondary BBR table on this disk.

Event ID

0x1406

Type

DISK

Severity

WARNING

Parameters

Disk ID

Message

Secondary BBR table on HDDx is corrupt

Description

The controller failed to access the secondary BBR table on hddx
and the table was non-trustable. However, the primary BBR table
still works.

Advice

Start to monitor more carefully the status of the primary BBR table
on this disk.

Event ID

0x1407

Type

DISK

Severity

WARNING

Parameters

Disk ID

Message

Both BBR tables on HDDx are corrupt

Description

The controller failed to access both primary and secondary BBR
tables on hddx, and the tables were non-trustable. In this case,
the BBR functions cannot work any more.

Advice

Replace with new disks to prevent from data loss.

Event ID

0x082a

Type

DISK

Severity

INFO

Parameters

Disk ID

Message

HDDx cache is enabled

Description

Disk cache of hddx was enabled by user.

Advice

None

Event ID

0x082b

Type

DISK

Severity

INFO

Parameters

Disk ID

Message

HDDx cache is disabled

Description

Disk cache of hddx was enabled by user.

Advice

None