beautypg.com

Accusys ExaRAID GUI User Manual

Page 324

background image

Appendix

D-35

Event ID

0x0816

Type

DISK

Severity

WARNING

Parameters

Disk ID

Message

Write both metadata on HDDx failed

Description

The controller failed to access both primary and secondary RAID
metadata on hddx, and the RAID metadata was invalid. In this
case, hddx will be set to faulty, and disk rebuilding will be started,
if needed.

Advice

None

Event ID

0x0821

Type

DISK

Severity

WARNING

Parameters

Disk ID

Message

Read primary metadata on HDDx failed

Description

The controller failed to access the primary RAID metadata stored
on hddx and the metadata was non-trustable. However, the
secondary RAID metadata still works.

Advice

Start to monitor more carefully the status of the secondary RAID
metadata on this disk.

Event ID

0x0822

Type

DISK

Severity

WARNING

Parameters

Disk ID

Message

Read both metadata on HDDx failed

Description

The controller failed to access both primary and secondary RAID
metadata on hddx, and the RAID metadata was non-trustable.
In this case, hddx will be set to faulty, and disk rebuilding will be
started, if needed.

Advice

Start to monitor more carefully the status of the primary RAID
metadata on this disk.

Event ID

0x0823

Type

DISK

Severity

WARNING

Parameters

Disk ID

Message

Primary metadata checksum error on HDDx failed

Description

The primary RAID metadata stored on hddx was non-trustable.
However, the secondary RAID metadata still works.

Advice

None

Event ID

0x0824

Type

DISK

Severity

WARNING

Parameters

Disk ID

Message

Secondary metadata checksum error on HDDx failed

Description

The secondary RAID metadata stored on hddx was non-trust-
able. However, the primary RAID metadata still works.

Advice

None