beautypg.com

Accusys ExaRAID GUI User Manual

Page 320

background image

Appendix

D-31

• Bad block handling

Event ID

0x080d

Type

DISK

Severity

WARNING

Parameters

Disk ID

Message

DST on HDDx completed with electrical error

Description

DST on hddx completed with electrical error.

Advice

The disk failed or will fail soon, replace the hard disk.

Event ID

0x080e

Type

DISK

Severity

WARNING

Parameters

Disk ID

Message

DST on HDDx completed with unknown test element error

Description

DST on hddx completed with error but the failed elements are
unknown.

Advice

The disk failed or will fail soon, replace the hard disk.

Event ID

0x1401

Type

DISK

Severity

WARNING

Parameters

Start Sector
NO, End
Sector NO,
Disk ID

Message

Bad blocks between sector x and sector y on HDDz detected

Description

A bad block starting from sector x on hddy was detected by the
controller.

Advice

If the number of bad blocks detected is growing exceptionally
fast or beyond a reasonable number, consider to conduct diag-
nostics and replace with new disks. If there is no subsequent
event notifying the recovery or reallocation of the bad block
detected, data on the bad block is lost.

Event ID

0x1404

Type

DISK

Severity

WARNING

Parameters

Start Sector
NO, End
Sector NO,
Disk ID

Message

Bad blocks between sector x and sector y on HDDz recovered

Description

A bad block starting from sector x on hddy was recovered by
the controller.

Advice

If the number of bad blocks detected grows exceptionally fast or
beyond a reasonable number, consider to conduct diagnostics
and replace with new disks.