Accusys ExaRAID GUI User Manual
Page 320

Appendix
D-31
• Bad block handling
Event ID
0x080d
Type
DISK
Severity
WARNING
Parameters
Disk ID
Message
DST on HDDx completed with electrical error
Description
DST on hddx completed with electrical error.
Advice
The disk failed or will fail soon, replace the hard disk.
Event ID
0x080e
Type
DISK
Severity
WARNING
Parameters
Disk ID
Message
DST on HDDx completed with unknown test element error
Description
DST on hddx completed with error but the failed elements are 
unknown.
Advice
The disk failed or will fail soon, replace the hard disk.
Event ID
0x1401
Type
DISK
Severity
WARNING
Parameters
Start Sector 
NO, End 
Sector NO, 
Disk ID
Message
Bad blocks between sector x and sector y on HDDz detected
Description
A bad block starting from sector x on hddy was detected by the 
controller.
Advice
If the number of bad blocks detected is growing exceptionally 
fast or beyond a reasonable number, consider to conduct diag-
nostics and replace with new disks. If there is no subsequent 
event notifying the recovery or reallocation of the bad block 
detected, data on the bad block is lost.
Event ID
0x1404
Type
DISK
Severity
WARNING
Parameters
Start Sector 
NO, End 
Sector NO, 
Disk ID
Message
Bad blocks between sector x and sector y on HDDz recovered
Description
A bad block starting from sector x on hddy was recovered by 
the controller.
Advice
If the number of bad blocks detected grows exceptionally fast or 
beyond a reasonable number, consider to conduct diagnostics 
and replace with new disks.