Sitrans p measuring instruments for pressure, Z series for gage and absolute pressure 2/9 – Siemens SITRANS P User Manual
Page 9
SITRANS P measuring instruments for pressure
Transmitters for gage, absolute and differential pressure
Z series for gage and absolute pressure
2/9
Siemens FI 01 · 2009
2
Please note:
• It is not possible to have a smaller span than the smallest span of the device of the entire device range.
• The value must not fall below the minimum permissible operating pressure of the special measuring range of the selected
measuring cell.
• The required span of the device must lie between the smallest and the largest possible span of the entire device range.
■
Selection and Ordering data
Order No.
Order code
SITRANS P pressure transmitters for pressure, series Z for gage and absolute pressure
2 or 3-wire system, rising characteristic curve
D)
7 MF 1 5 6 4 -
7 7 7 7 7
-
7 7 7
1
777
Measuring range
perm. working pressure
Burst pressure
Min.
Max.
For gage pressure
with metal measuring cell
0 ... 100 mbar g
(0 ... 1.45 psi g)
-0,6 bar g
(-8.7 psi g)
0,6 bar g
(8.7 psi g)
1 bar g
(14.5 psi g)
}
3 A A 0
0 ... 160 mbar g
(0 ... 2.32 psi g)
-0,6 bar g
(-8.7 psi g)
0,6 bar g
(8.7 psi g)
1 bar g
(14.5 psi g)
}
3 A B 0
0 ... 250 mbar g
(0 ... 3.63 psi g)
-1 bar g
(-14.5 psi g) 1 bar g
(14.5 psi g)
1.7 bar g
(25 psi g)
}
3 A C 0
0 ... 400 mbar g
(0 ... 5.80 psi g)
-1 bar g
(-14.5 psi g) 1 bar g
(14.5 psi g)
1.7 bar g
(25 psi g)
}
3 A D 0
0 ... 600 mbar g
(0 ... 8.70 psi g)
-1 bar g
(-14.5 psi g) 3 bar g
(43.5 psi g)
5 bar g
(72 psi g)
}
3 A G 0
Other version for measuring range < 1 bar (< 14.5 psi g), add Order code and plain text:
measuring range: ... up to ... mbar g (psi g)
1)
9 A C 0
H 1 Y
with ceramic measuring cell
0 ... 1 bar g
(0 ... 14.5 psi g)
-0,4 bar g
(-5.8 psi g)
2 bar g
(30 psi g)
5 bar g
(72 psi g)
}
3 B A
0 ... 1.6 bar g
(0 ... 23.2 psi g)
-0,4 bar g
(-5.8 psi g)
3,2 bar g
(45 psi g)
5 bar g
(72 psi g)
}
3 B B
0 ... 2.5 bar g
(0 ... 36.3 psi g)
-0,8 bar g
(-11.6 psi g) 5 bar g
(72 psi g)
12 bar g
(175 psi g)
}
3 B D
0 ... 4 bar g
(0 ... 58.0 psi g)
-0,8 bar g
(-11.6 psi g) 8 bar g
(115 psi g)
12 bar g
(175 psi g)
}
3 B E
0 ... 6 bar g
(0 ... 87.0 psi g)
-1 bar g
(-14.5 psi g) 12 bar g
(175 psi g)
25 bar g
(360 psi g)
}
3 B G
0 ... 10 bar g
(0 ... 145 psi g)
-1 bar g
(-14.5 psi g) 20 bar g
(290 psi g)
50 bar g
(725 psi g)
}
3 C A
0 ... 16 bar g
(0 ... 232 psi g)
-1 bar g
(-14.5 psi g) 32 bar g
(460 psi g)
50 bar g
(725 psi g)
}
3 C B
0 ... 25 bar g
(0 ... 363 psi g)
-1 bar g
(-14.5 psi g) 50 bar g
(725 psi g)
120 bar g
(1750 psi g)
}
3 C D
0 ... 40 bar g
(0 ... 580 psi g)
-1 bar g
(-14.5 psi g) 80 bar g
(1150 psi g) 120 bar g
(1750 psi g)
}
3 C E
0 ... 60 bar g
(0 ... 870 psi g)
-1 bar g
(-14.5 psi g) 120 bar g
(1750 psi g) 250 bar g
(3600 psi g)
}
3 C G
0 ... 100 bar g
(0 ... 1450 psi g)
-1 bar g
(-14.5 psi g) 200 bar g
(2900 psi g) 450 bar g
(6525 psi g)
}
3 D A
0 ... 160 bar g
(0 ... 2320 psi g)
-1 bar g
(-14.5 psi g) 320 bar g
(4640 psi g) 450 bar g
(6525 psi g)
}
3 D B
0 ... 250 bar g
(0 ... 3626 psi g)
-1 bar g
(-14.5 psi g) 500 bar g
(7250 psi g) 650 bar g
(9425 psi g)
}
3 D D
0 ... 400 bar g
(0 ... 5802 psi g)
-1 bar g
(-14.5 psi g) 600 bar g
(8700 psi g) 650 bar g
(9425 psi g)
}
3 D E
Other version for measuring range
≥ 1 bar g (≥ 14.5 psi g), add Order code and plain text:
measuring range: ... up to... bar (psi g)
1)
9 A A
H 1 Y
For absolute pressure
0 ... 600 mbar a
(0 ... 8.7 psi a)
0 bar a
(0 psi a)
3 bar a
(43.5 psi a)
5 bar a
(72 psi a)
}
J)
5 A G 0
0 ... 1 bar a
(0 ... 14.5 psi a)
0 bar a
(0 psi a)
2 bar a
(30 psi a)
5 bar a
(72 psi a)
}
J)
5 B A
0 ... 1.6 bar a
(0 ... 23.2 psi a)
0 bar a
(0 psi a)
3,2 bar a
(45 psi a)
5 bar a
(72 psi a)
}
J)
5 B B
0 ... 2.5 bar a
(0 ... 36.3 psi a)
0 bar a
(0 psi a)
5 bar a
(72 psi a)
12 bar a
(175 psi a)
}
J)
5 B D
0 ... 4 bar a
(0 ... 58.0 psi a)
0 bar a
(0 psi a)
8 bar a
(115 psi a)
12 bar a
(175 psi a)
}
J)
5 B E
0 ... 6 bar a
(0 ... 87.0 psi a)
0 bar a
(0 psi a)
12 bar a
(175 psi a)
25 bar a
(360 psi a)
}
J)
5 B G
0 ... 10 bar a
(0 ... 145 psi)
0 bar a
(0 psi a)
20 bar a
(290 psi a)
50 bar a
(725 psi a)
}
J)
5 C A
0 ... 16 bar a
(0 ... 232 psi)
0 bar a
(0 psi a)
32 bar a
(460 psi a)
50 bar a
(725 psi a)
}
J)
5 C B
Other version for measuring range < 1 bar (< 14.5 psi a), add Order code and plain text:
measuring range: ... up to ... mbar a (psi a)
J)
9 A B 0
H 1 Y
}
Available ex stock
D) Subject to export regulations AL: N, ECCN: EAR99H.
J) Subject to export regulations AL: 9I999, ECCN: EAR99.
1)
The transmitters can also be ordered with special measuring ranges, e.g. the transmitter with the 1 bar measuring cell (14.5 psi measuring cell):
-0.2 ... +0.8 bar g (-2.9 ... +11.6 psi g) or
-0.4 ... +0.6 bar g (-5.8 ... +8.7 psi g) or ..., however start-of-scale value not under -0.4 bar g (-5.8 psi g), also see column "min. perm. operating pressure"
© Siemens AG 2008