Sitrans p measuring instruments for pressure – Siemens SITRANS P User Manual
Page 61
SITRANS P measuring instruments for pressure
Transmitters for gage pressure for the paper industry
SITRANS P300 with PMC connection
2/61
Siemens FI 01 · 2009
2
F) Subject to export regulations AL: 9I999, ECCN: N.
Selection and Ordering data
Order No.
SITRANS P300 pressure transmitters with PMC
connection, single-chamber measuring housing,
rating plate inscription in English
4 ... 20 mA/HART
F)
7 M F 8 1 2 3 -
PROFIBUS PA
F)
7 M F 8 1 2 4 -
FOUNDATION Fieldbus (FF)
F)
7 M F 8 1 2 5 -
7 7 7 7 7
-
7 7 7 7
Measuring cell filling
Measuring cell cleaning
Silicone oil
Standard
1
Inert liquid
Cleanliness level 2 to
DIN 25410
3
Span
1 bar g
(14.5 psi g)
B
4 bar g
(58 psi g)
C
16 bar g
(232 psi g)
D
Wetted parts materials
Seal diaphragm
Measuring cell
Hastelloy
Stainless steel
B
Process connection
• PMC Style Standard: Thread 1½"
2
• PMC Style Mini bolt: 1" front-flush (min. span: 500
mbar (7.25 psi), can not be ordered with mit 1-bar
(14.5 psi) measuring cell (Option B))
3
Non-wetted parts materials
• Stainless steel, deep-drawn and electrolytically
polished
4
Version
• Standard version
1
Explosion protection
• None
A
• With ATEX, Type of protection:
- "Intrinsic safety (EEx ia)"
B
• Zone 20/21/22
1)
1)
Can only be ordered in conjunction with electrical connection Option A.
C
• Ex nA/nL (zone 2)
2)
2)
Can only be ordered in conjunction with electrical connection Option B, C,
F or G.
E
• With FM + CSA, Type of protection:
- "Intrinsic Safe (is)" (planned)
M
Electrical connection / cable entry
• Screwed gland M20x1.5 (Polyamide)
3)
3)
Only together with HART electronics.
A
• Screwed gland M20x1.5 (metal)
B
• Screwed gland M20x1.5 (stainless steel)
C
• M12 connector (without cable socket)
F
• M12 connector (stainless steel, without cable socket)
G
• ½-14 NPT thread, metal
4)
4)
Without cable gland.
H
• ½-14 NPT thread, stainless steel
4)
J
Display
• Without display, with keys, closed lid
3)
1
• With display and keys, closed lid
2
• With display and keys, lid with glass pane
(setting on HART devices: mA, on PROFIBUS PA
and FOUNDATION Fieldbus devices: pressure unit)
6
• With display (setting acc. to specifications, Order
code "Y21" or "Y22" required), lid with glass pane
7
Power supply units
see "SITRANS I power supply units and isolation
amplifiers".
Included in delivery of the device:
• Brief instructions (Leporello)
• CD-ROM with detailed documentation
• Sealing ring
Selection and Ordering data
Order code
Further designs
HART PA
FF
Add "-Z" to Order No. and specify Order
code.
Cable socket for M12 plug
• Metal
A50
9
9
9
9
• Stainless steel
A51
9
9
9
9
Rating plate inscription
(instead of English)
• German
B10
9
9
9
9
9
9
• French
B12
9
9
9
9
9
9
• Spanish
B13
9
9
9
9
9
9
• Italian
B14
9
9
9
9
9
9
English rating plate
B21
9
9
9
9
9
9
Pressure units in inH
2
O or psi
Quality inspection certificate (Factory cali-
bration) to IEC 60770-2
C11
9
9
9
9
9
9
Acceptance test certificate
C12
9
9
9
9
9
9
To EN 10204-3.1
Factory certificate
C14
9
9
9
9
9
9
To EN 10204-2.2
Set output signal to upper limit of 22.0 mA D05
9
9
9
9
9
9
Type of protection IP68
D12
9
9
9
9
9
9
Mounting
• Weldable sockets for standard 1½" threaded
connection
P01
9
9
9
9
9
9
• Weldable socket for mini bolt connection 1"
(incl. screw 5/16-18 UNC-2B and washer)
P02
9
9
9
9
9
9
Additional data
Add "-Z" to Order No. and
specify Order code.
Measuring range to be set
Y01
9
9
Specify in plain text (max. 5 digits):
Y01: ... up to ... mbar, bar, kPa, MPa, psi
Measuring point number (TAG No.)
Y15
9
9
9
9
9
9
Max. 16 characters, specify in plain text: Y15:
......
Measuring point text
Y16
9
9
9
9
9
9
Max. 27 characters, specify in plain text: Y16:
......
Entry of HART address (TAG)
Y17
9
9
Max. 8 characters, specify in plain text:
Y17: ...........................................
Setting of pressure indication in pressure
units
Y21
9
9
9
9
9
9
Specify in plain text (standard setting: mA):
Y21: mbar, bar, kPa, MPa, psi, ...
Note: The following pressure units can be
selected:
bar, mbar, mm H
2
O
*)
, inH
2
O
*)
, ftH
2
O
*)
,
mmHG, inHG, psi, Pa, kPa, MPa, g/cm
2
,
kg/cm
2
, Torr, ATM or %
*) ref. temperature 20 °C
Setting of pressure indication in non-pres-
sure units
Y22 +
Y01
9
9
Specify in plain text:
Y22: ..... up to ..... l, m
3
, m, USg, ...
(specification of measuring range in pressure
units "Y01" is essential, unit with max. 5 char-
acters)
Preset bus address
Y25
9
9
9
9
Specify in plain text:
Y25: .....................
Only "Y01" and "Y21" can be factory preset
9
9 = available
© Siemens AG 2008