Selection and Ordering data

Order No.

SITRANS P pressure transmitters for absolute
pressure, from the differential pressure,
series DS III HART

F)

7 M F 4 3 3 3 -

7 7 7 7 7

-

7 7 7 7

Measuring cell filling

Measuring cell
cleaning

Silicone oil

Standard

1

Inert liquid

1)

Grease-free

3

Span
8.3 ... 250 mbar a

(0.12 ... 3.63 psi a)

E)

D

43 ... 1300 mbar a

(0.62 ... 18.9 psi a)

E)

F

0.16 ... 5 bar a

(2.32 ... 72.5 psi a)

E)

G

1 ... 30 bar a

(14.5 ... 435 psi a)

H

5.3 ... 100 bar a

(76.9 ... 1450 psi a)

K E

Wetted parts materials
Seal diaphragm

Parts of measuring cell

Stainless steel

Stainless steel

A

Hastelloy

Stainless steel

B

Hastelloy

Hastelloy

C

Tantalum

Tantalum

E

Monel

Monel

E)

H

Gold

Gold

L

Version for diaphragm seal

2)3)4)

Y

Process connection
Female thread ¼-18 NPT with flange connection
• Sealing screw opposite process connection

- Mounting thread

7

/

16

-20 UNF to EN 61518

2

- Mounting thread M10 to DIN 19213

(only for replacement needs)

0

• Vent on side of process flange

5)

- Mounting thread

7

/

16

-20 UNF to EN 61518

6

- Mounting thread M10 to DIN 19213

(only for replacement needs)

4

Non-wetted parts materials
Process flange screws

Electronics housing

Stainless steel

Die-cast aluminium

2

Stainless steel

Stainless steel precision
casting

6)

3

Version
• Standard version

1

• International version, English label inscriptions,

documentation in 5 languages on CD

2

Explosion protection
• Without

A

• With ATEX, Type of protection:

- "Intrinsic safety (EEx ia)"

B

- "Explosion-proof (EEx d)"

7)

D

- "Intrinsic safety and explosion-proof enclosure

(EEx ia + EEx d)"

8)

P

- "Ex nA/nL (zone 2)"

E

- "Intrinsic safety, explosion-proof enclosure and

dust explosion protection (EEx ia + EEx d +
Zone 1D/2D)"

8)

R

• With FM + CSA, Type of protection:

- "Intrinsic safety and explosion-proof

(is + xp)"

7)

N C

Electrical connection / cable entry
• Screwed gland Pg 13.5

9)

A

• Screwed gland M20x1.5

B

• Screwed gland ½-14 NPT

C

• Han 7D plug (plastic housing) incl. mating

connector

9)

D

• Plug M12 (metal)

10)

F

Display
• Without indicator

0

• Without visible digital indicator (digital indicator

hidden, setting: mA)

}

1

• With visible digital indicator

6

• With customer-specific digital indicator (setting

as specified, Order code "Y21" or required)

7

Power supply units

see "SITRANS I power supply units and isolation

amplifiers".

Factory-mounting of shut-off valves and valve manifolds see page
2/142.

Included in delivery of the device:
• Brief instructions (Leporello)
• CD-ROM with detailed documentation
• Sealing plug(s) or sealing screw(s) for the process flanges(s)

1)

For oxygen applications, add Order code E10.

2)

Version 7MF4333-1DY... only up to max. span 200 mbar a (2.9 psi a).

3)

When the manufacture’s certificate M (calibration certificate) has to be
ordered for transmitters with diaphragm seals, it is recommended only to
order this certificate exclusively with the diaphragm seals. The measuring
accuracy of the total combination is certified here.

4)

Whe the acceptance test certificate 3.1 for transmitters with direct-con-
nected diaphragm seals is ordered, this certificate must also be ordered
with the corresponding seals.

5)

Not for span "5.3 ... 100 bar a (76.9 ... 1450 psi a)". Position of the top vent
valve in the process flange (see dimensional drawing).

6)

Not together with Electrical connection „Screwed gland Pg 13.5“ and
„Han7D plug“.

7)

Without cable gland, with blanking plug

8)

With enclosed cable gland EEx ia and blanking plug

9)

Not together with type of protection "Explosion-proof" and and type of
protection "Ex nA".

10)

Not together with types of protection "Explosion-proof" or "Intrinsic safety
and explosion-proof"

Selection and Ordering data

Order No.

SITRANS P pressure transmitters for absolute
pressure, from the differential pressure,
series DS III HART

F)

7 M F 4 3 3 3 -

7 7 7 7 7

-

7 7 7 7