Sitrans p measuring instruments for pressure, Ds iii series for gage pressure 2/76 – Siemens SITRANS P User Manual
Page 76
SITRANS P measuring instruments for pressure
Transmitters for gage, absolute and differential pressure, flow and level
DS III series
for gage pressure
2/76
Siemens FI 01 · 2009
2
Selection and Ordering data
Order code
Further designs
Add "-Z" to Order No. and specify Order code.
HART PA
FF
Pressure transmitter with mounting
bracket made of:
• Steel
A01
9
9
9
9
9
9
• Stainless steel
A02
9
9
9
9
9
9
Plug
• Han 7D (metal, gray)
A30
9
9
• Han 8U (instead of Han 7D)
A31
9
9
Cable sockets for M12 connectors (metal)
A50
9
9
9
9
9
9
Rating plate inscription
(instead of German)
• English
B11
9
9
9
9
9
9
• French
B12
9
9
9
9
9
9
• Spanish
B13
9
9
9
9
9
9
• Italian
B14
9
9
9
9
9
9
English rating plate
B21
9
9
9
9
9
9
Pressure units in inH
2
O or psi
Quality inspection certificate (Factory cali-
bration) to IEC 60770-2
1)
1)
When the manufacture’s certificate M (calibration certificate) has to be
ordered for transmitters with diaphragm seals, it is recommended only to
order this certificate exclusively with the diaphragm seals. The measuring
accuracy of the total combination is certified here.
C11
9
9
9
9
9
9
Acceptance test certificate
2)
2)
Whe the acceptance test certificate 3.1 for transmitters with direct-con-
nected diaphragm seals is ordered, this certificate must also be ordered
with the corresponding seals.
C12
9
9
9
9
9
9
To EN 10204-3.1
Factory certificate
C14
9
9
9
9
9
9
To EN 10204-2.2
"Functional Safety (SIL)" certificate
C20
9
9
"PROFIsafe“ certificate and protocol
C21
9
9
Setting of upper limit of output signal to
22.0 mA
D05
9
9
Manufacturer's declaration acc. to NACE
D07
9
9
9
9
9
9
Type of protection IP68
D12
9
9
9
9
9
9
(not together with 7D/
Han 8U plug, cable gland Pg 13.5)
Digital indicator alongside the input keys
D27
9
9
9
9
9
9
(only together with the devices 7MF4033-
....0-.A.6 or -.A.7-Z, Y21 or Y22 + Y01)
Supplied with oval flange
D37
9
9
9
9
9
9
(1 item), PTFE packing and screws in thread
of oval flange
Use in or on zone 1D/2D
E01
9
9
9
9
9
9
(only together with type of protection
"Intrinsic safety (EEx ia)")
Use on zone 0
E02
9
9
9
9
9
9
(only together with type of protection
"Intrinsic safety (EEx ia)")
Oxygen application
E10
9
9
9
9
9
9
(max. 120 bar g (1740 psi g) at 60°C (140 °F)
for oxygen measurement and inert liquid)
Explosion-proof "Intrinsic safety" to
INMETRO (Brazil)
E25
9
9
9
9
9
9
(only for transmitter 7MF4...-.....-.B..)
Explosion-proof "Intrinsic safety" to
NEPSI (China)
E55
9
9
9
9
9
9
(only for transmitter 7MF4...-.....-.B..)
Explosion protection "Explosion-proof" to
NEPSI (China)
E56
9
9
9
9
9
9
(only for transmitter 7MF4...-.....-.D..)
Explosion-proof "Zone 2" to NEPSI (China) E57
9
9
9
9
9
9
(only for transmitter 7MF4...-.....-.E..)
Selection and Ordering data
Order code
Additional data
Add "-Z" to Order No. and specify Order
code.
HART PA
FF
Measuring range to be set
Y01
9
9
Specify in plain text (max. 5 digits):
Y01: ... up to ... mbar, bar, kPa, MPa, psi
Measuring point number (TAG No.)
Y15
9
9
9
9
9
9
Max. 16 characters, specify in plain text:
Y15: ...........................................
Measuring point text
Y16
9
9
9
9
9
9
Max. 27 characters, specify in plain text:
Y16: ...........................................
Entry of HART address (TAG)
Y17
9
9
Max. 8 characters, specify in plain text:
Y17: ...........................................
Setting of pressure indication in pressure
units
Y21
9
9
9
9
9
9
Specify in plain text (standard setting: mA):
Y21: mbar, bar, kPa, MPa, psi, ...
Note:
The following pressure units can be selected:
bar, mbar, mm H
2
O
*)
, inH
2
O
*)
, ftH
2
O
*)
,
mmHG, inHG, psi, Pa, kPa, MPa, g/cm
2
,
kg/cm
2
, Torr, ATM oder %
*) ref. temperature 20 °C
Setting of pressure indication in
non-pressure units
Y22 +
Y01
9
9
Specify in plain text:
Y22: ..... up to ..... l/min, m
3
/h, m, USgpm, ...
(specification of measuring range in
pressure units "Y01" is essential, unit with
max. 5 characters)
Preset bus address
Y25
9
9
(possible between 1 and 126)
Specify in plain text:
Y25: .....................
Only "Y01", "Y21", "Y22", "Y25" and "D05" can be factory preset
9
9 = available
Ordering example
Item line:
7MF4033-1EA00-1AA7-Z
B line:
A01 + Y01 + Y21
C line:
Y01: 10 ... 20 bar (145 ... 290 psi)
C line:
Y21: bar (psi)
© Siemens AG 2008