Way valve manifolds dn 5, Sitrans p measuring instruments for pressure – Siemens SITRANS P User Manual
Page 198
SITRANS P measuring instruments for pressure
Fitttings - Shut-off valves for gage and absolute pressure transmitters
2-way valve manifolds DN 5
2/198
Siemens FI 01 · 2009
2
■
Overview
The two-way valve manifold DN 5 (7MF9401-2..) is used to shut
off and vent the line with the measured medium, and to test the
connected pressure gage or transmitter.
■
Benefits
• Available for aggressive and non-aggressive liquids and
gases
• Two connection versions available
- For flanging to pressure transmitters
- With nipple for connection of pressure gages and pressure
transmitters for pressure
• Max. working pressure 420 bar, with version for oxygen max.
100 bar
■
Application
The 2-way valve manifold is available in versions for aggressive
and non-aggressive liquids and gases.
Mounting plates are available for wall mounting, for securing to
mounting racks or for pipe mounting.
■
Design
The 2-way valve manifold DN 5 has 3 connections:
• A process connection (pipe union with ferrule Ø 12 mm)
• A connection for a pressure gage (flange or nipple)
• A test connection (thread G
3
/
8
)
The 2-fold valve manifold DN 5 also has an operating valve and
a test valve, each with an internal spindle thread.
Materials used
2-way valve manifold DN 5 for flanging to pressure transmitters
■
Function
The characteristic of the pressure measuring instrument or pres-
sure transmitter can be tested through the test connection.
A pressure gage for local display can be connected to the test
connection.
The two-way valve manifold DN 5 can be used in addition to shut
off and vent the line with the measured medium.
■
Accessories
Accessory set for 2-way valve manifold DN 5 for flanging
• A31: 2 screws
7
/
16
-20 UNF x 2
1
/
8
inch to ASME B18.3,
1 flat gasket
• A34: 2 screws
7
/
16
-20 UNF x 2
1
/
8
inch to ASME B18.3,
1 O-ring (FPM 90)
• A11: 2 screws M10x55 to DIN EN 4762, 2 washers,
1 flat gasket
• A15 (suitable for oxygen): 2 screws M10x55 to DIN EN 4762,
2 washers, 1 flat gasket
• A16: 2 screws M10x55 to DIN EN 4762, 2 washers,
1 flat gasket (FPM 90)
Note: M10 screws only permissible up to PN 160!
Washers Ø 10.5 to DIN 125
Flat gaskets made of PTFE, max. 420 bar, 80 °C
O-ring to DIN 3771, 20 x 2.65 - S – FPM90, max. 420 bar, 120 °C
Mounting plate
Made of electrogalvanized sheet-steel
• M11: For wall mounting or for securing on rack (72 mm grid)
Scope of delivery:
- 1 mounting plate with bolts for mounting on valve manifold
• M12: For pipe mounting
Scope of delivery:
- 1 mounting plate M11
- 2 pipe brackets with nuts and washers for pipes with max.
Ø 60.3 mm
Valve manifold 100 bar, suitable for oxygen
• S12: (only in combination with versions for aggressive liquids
and gases): Suitable for oxygen
For non-aggressive liquids and
gases
For aggressive
liquids and gases
Component Material
Mat. No.
Material
Mat. No.
Housing
P250GH
1.0460
X 6
CrNiMoTi
17 12 2
1.4571/
316Ti
Head parts C 35
1.0501
Spindles
X 12 CrMoS 17
1.4104
Cones
X 35 CrMo 17 hard-
ened and tempered
1.4122
Valve seats X 6 CrNiMoTi 17 12 2
1.4571/316Ti
Packings
PTFE
-
PTFE
-
© Siemens AG 2008