Influence of static pressure
• on the zero point
- 250 mbar (3.63 psi) measuring cell
≤ (0.3 ⋅ r)% per nominal pressure
≤ 0.3% per nominal pressure
- 600 mbar (8.7 psi) measuring cell
≤ (0.15 ⋅ r)% per nominal pressure
≤ 0.15% per nominal pressure
- 1600 and 5000 mbar (23.2 and 72.5 psi)
measuring cells
≤ (0.1 ⋅ r)% per nominal pressure
≤ 0.1% per nominal pressure
• on the span
≤ (0.1 ⋅ r)% per nominal pressure
≤ 0.1% per nominal pressure
Measured Value Resolution
-
3
⋅ 10
-5
of nominal measuring range
Rated operating conditions
Degree of protection (to EN 60529)
IP65
Process temperature
Note: Always take into account assignment of max. permissible working temperature to max. per-
missible working pressure of the respective flange connection!
• Measuring cell with silicone oil filling
-40 ... +100 °C (-40 ... +212 °F)
- High-pressure side
p
abs
≥ 1bar: -40 ... +175 °C (-40 ... +347 °F)
p
abs
≥ 1bar: -40 ... +80 °C (-40 ... +176 °F)
- Low-pressure side
-40 ... +100 °C (-40 ... +212 °F)
-20 ... +60 °C (-4 ... +140 °F) in conjunction with dust explosion protection
Ambient conditions
• Ambient temperature
- Digital indicators
-30 ... +85 °C (-22 ... +185 °F)
• Storage temperature
-50 ... +85 °C (-58 ... +185 °F)
• Climatic class
- Condensation
Permissible
• Electromagnetic compatibility
- Emitted interference and interference immu-
nity
To EN 61326 and NAMUR NE 21
Design
Weight (without options)
• To EN (pressure transmitter with mounting
flange, without tube)
≈ 11 ... 13 kg (≈ 24.2 ... 28.7 lb)
• To ASME (pressure transmitter with mounting
flange, without tube)
≈ 11 ... 18 kg (≈ 24.2 ... 39.7 lb)
Wetted parts materials
Poor in copper die-cast aluminium, GD-AlSi12 or stainless steel precision casting, mat. No. 1.4408
Housing material
High-pressure side
• Seal diaphragm of mounting flange
Stainless steel, mat. No. 1.4404/316L, Monel, mat. No. 2.4360, Hastelloy B2, mat. No. 2.4617,
Hastelloy C276, mat. No. 2.4819, Hastelloy C4, mat. No. 2.4610, tantalum, PTFE, ECTFE
Measuring cell filling
Silicone oil
Process connection
• High-pressure side
Flange to EN and ASME
• Low-pressure side
Female thread ¼-18 NPT and flange connection with mounting thread M10 to DIN 19213 or
7
/
16
-20 UNF to EN 61518
Power supply U
H
Supplied through bus
Terminal voltage on transmitter
10.5 ... 45 V DC
10.5 ... 30 V DC in intrinsically-safe mode
-
Separate 24 V power supply necessary
-
No
Bus voltage
• Not Ex
-
9 ... 32 V
• With intrinsically-safe operation
-
9 ... 24 V
Current consumption
• Basic current (max.)
-
12.5 mA
• Startup current
≤ basic current
-
Yes
• Max. current in event of fault
-
15.5 mA
Fault disconnection electronics (FDE) available
-
Yes
SITRANS P, DS III series for level
HART
PROFIBUS PA or FOUNDATION Fieldbus