Sitrans p measuring instruments for pressure – Siemens SITRANS P User Manual
Page 112
SITRANS P measuring instruments for pressure
Transmitters for gage, absolute and differential pressure, flow and level
DS III series
for differential pressure and flow
2/112
Siemens FI 01 · 2009
2
Selection and Ordering data
Order No.
SITRANS P pressure transmitters for differen-
tial pressure and flow, Series DS III HART
PN 32/160 (MWP 464/2320 psi)
7 M F 4 4 3 3 -
7 7 7 7 7
-
7 7 7 7
Measuring cell filling
Measuring cell
cleaning
Silicone oil
Standard
}
1
Inert liquid
1)
Grease-free
3
Span
PN 32 (MWP 464 psi)
1 ... 20 mbar
2)
(0.4015 ... 8.03 inH
2
O)
}
B
PN 160 (MWP 2320 psi)
1 ... 60 mbar
(0.4015 ... 24.09 inH
2
O)
}
C
2.5 ... 250 mbar
(1.004 ... 100.4 inH
2
O)
}
D
6 ... 600 mbar
(2.409 ... 240.9 inH
2
O)
}
E
16 ... 1600 mbar
(6.424 ... 642.4 inH
2
O)
}
F
50 ... 5000 mbar
(20.08 ... 2008 inH
2
O)
}
G
0.3 ... 30 bar
(4.35 ... 435 psi)
}
H
Wetted parts materials
(stainless steel process flanges)
Seal diaphragm
Parts of measuring cell
Stainless steel
Stainless steel
}
A
Hastelloy
Stainless steel
B
Hastelloy
Hastelloy
C
Tantalum
3)
Tantalum
E
Monel
3)
Monel
H
Gold
3)
Gold
L
Version for diaphragm seal
4)
5)
Y
Process connection
Female thread ¼-18 NPT with flange connection
• Sealing screw opposite process connection
- Mounting thread
7
/
16
-20 UNF to EN 61518
2
- Mounting thread M10 to DIN 19213
(only for replacement needs)
}
0
• Vent on side of process flange
2)
- Mounting thread
7
/
16
-20 UNF to EN 61518
6
- Mounting thread M10 to DIN 19213
(only for replacement needs)
4
Non-wetted parts materials
Process flange screws
Electronics housing
Stainless steel
Die-cast aluminium
}
2
Stainless steel
Stainless steel precision
casting
6)
3
Version
• Standard version
1
• International version, English label inscriptions,
documentation in 5 languages on CD
}
2
Explosion protection
• Without
A
• With ATEX, Type of protection:
- "Intrinsic safety (EEx ia)"
B
- "Explosion-proof (EEx d)"
7)
D
- "Intrinsic safety and explosion-proof
enclosure (EEx ia + EEx d)"
8)
P
- "Ex nA/nL (zone 2)"
E
- "Intrinsic safety, explosion-proof enclosure
and dust explosion protection
(EEx ia + EEx d + Zone 1D/2D)"
8)
}
R
• With FM + CSA, Type of protection:
- "Intrinsic safety and explosion-proof
(is + xp)"
7)
N C
Electrical connection / cable entry
• Screwed gland Pg 13.5
9)
A
• Screwed gland M20x1.5
}
B
• Screwed gland ½-14 NPT
C
• Han 7D plug (plastic housing) incl. mating
connector
10)
D
• M12 connectors (metal)
10)
F
Display
• Without indicator
0
• Without visible digital indicator (digital indicator
hidden, setting: mA)
}
1
• With visible digital indication
6
• With customer-specific digital indication (setting
as specified, Order code "Y21" or required)
7
}
Available ex stock
Power supply units
see "SITRANS I power supply units and isolation
amplifiers".
Factory-mounting of shut-off valves and valve manifolds see page
2/142.
Included in delivery of the device:
• Brief instructions (Leporello)
• CD-ROM with detailed documentation
• Sealing plug(s) or sealing screw(s) for the process flanges(s)
1)
For oxygen application, add Order code E10.
2)
Not suitable for connection of remote seal. Position of the top vent valve in
the process flanges (see dimensional drawing).
3)
Only together with max. spans 250, 1600, 5000 and 30000 mbar
(100.4, 240.9, 2008 inH
2
O and 435 psi)
4)
When the manufacture’s certificate M (calibration certificate) has to be
ordered for transmitters with diaphragm seals, it is recommended only to
order this certificate exclusively with the diaphragm seals. The measuring
accuracy of the total combination is certified here.
5)
Whe the acceptance test certificate 3.1 for transmitters with direct-con-
nected diaphragm seals is ordered, this certificate must also be ordered
with the corresponding seals.
6)
Not together with Electrical connection „Screwed gland Pg 13.5“ and
„Han7D plug“.
7)
Without cable gland, with blanking plug
8)
With enclosed cable gland EEx ia and blanking plug
9)
Not together with type of protection "Explosion-proof" and and type of
protection "Ex nA".
10)
Cannot be used together with the following types of protection:
"Explosion-proof" and "Intrinsic safety and explosion-proof"
Selection and Ordering data
Order No.
SITRANS P pressure transmitters for differen-
tial pressure and flow, Series DS III HART
PN 32/160 (MWP 464/2320 psi)
7 M F 4 4 3 3 -
7 7 7 7 7
-
7 7 7 7
© Siemens AG 2008