Sitrans p measuring instruments for pressure – Siemens SITRANS P User Manual
Page 40
SITRANS P measuring instruments for pressure
Transmitters for food, pharmaceuticals and biotechnology
SITRANS P300 for gage and absolute pressure
2/40
Siemens FI 01 · 2009
2
F) Subject to export regulations AL: 9I999, ECCN: N.
Selection and Ordering data
Order No.
SITRANS P300 pressure transmitters for gage
and absolute pressure with front-flush membrane,
single-chamber measuring housing, rating plate
inscription in English
4 ... 20 mA/HART
F)
7 M F 8 1 2 3 -
PROFIBUS PA
F)
7 M F 8 1 2 4 -
FOUNDATION Fieldbus (FF)
F)
7 M F 8 1 2 5 -
7 7 7 7 7
-
7 7 7 7
Measuring cell filling
Measuring cell cleaning
Silicone oil
Standard
1
Inert liquid
Cleanliness level 2 to
DIN 25410
3
FDA compliant fill fluid
• Neobee oil
Standard
4
max. span
0.01 ... 1 bar g
(0.15 ... 14.5 psi g)
B
0.04 ... 4 bar g
(0.58 ... 58 psi g)
C
0.16 ... 16 bar g
(2.32 ... 232 psi g)
D
0.63 ... 63 bar g
(9.14 ... 914 psi g)
E
13 ... 1300 mbar a
1)
(0.19 ... 18.9 psi a)
S
0.05 ... 5 bar a
1)
(0.7 ... 72.5 psi a)
T
0.03 ... 30 bar a
1)
(4.35 ... 435 psi a)
U
Wetted parts materials
Seal diaphragm
Measuring cell
Stainless steel
Stainless steel
A
Process connection
• Flange version with Order code M.., N.., R.. or Q..
(see "Further designs")
7
Non-wetted parts materials
• Stainless steel, deep-drawn and electrolytically
polished
4
Version
• Standard version
1
Explosion protection
• Without
A
• With ATEX, Type of protection:
- "Intrinsic safety (EEx ia)"
B
• Zone 20/21/22
2)
C
• Ex nA/nL (zone 2)
3)
E
• With FM „Intrinsic safe“ (cFM
US
)
M
Electrical connection / cable entry
• Screwed gland M20x1.5 (Polyamide)
4)
A
• Screwed gland M20x1.5 (metal)
B
• Screwed gland M20x1.5 (stainless steel)
C
• M12 connector (without cable socket)
F
• M12 connector (stainless steel, without cable socket)
G
• ½-14 NPT thread, metal
5)
H
• ½-14 NPT thread, stainless steel
5)
J
Display
• Without display, with keys, closed lid
4)
1
• With display and keys, closed lid
2
• With display and keys, lid with macrolon washer
(setting on HART devices: mA,
on PROFIBUS PA and FOUNDATION Fieldbus
devices: pressure units)
4
• With display (setting acc. to specifications, Order
code "Y21" or "Y22" required), lid with macrolon
washer
5
• With display and keys, lid with glass pane
(setting on HART devices: mA,
on PROFIBUS PA and FOUNDATION Fieldbus
devices: pressure units)
6
• With display (setting acc. to specifications, Order
code "Y21" or "Y22" required), lid with glass pane
7
Power supply units
see "SITRANS I power supply units and isol. amplifiers".
Included in delivery of the device:
• Brief instructions (Leporello)
• CD-ROM with detailed documentation
1)
Not with temperature decoupler P00 and P10, not for process connections
R02, R04, R10 and R11, and can only be ordered in conjunction with sili-
cone oil.
2)
Can only be ordered in conjunction with electrical connection Option A.
3)
Can only be ordered in conjunction with electrical connection Option B, C,
F or G.
4)
Only together with HART electronics.
5)
Without cable gland.
Selection and Ordering data
Order No.
SITRANS P300 pressure transmitters for gage
and absolute pressure with front-flush membrane,
single-chamber measuring housing, rating plate
inscription in English
4 ... 20 mA/HART
F)
7 M F 8 1 2 3 -
PROFIBUS PA
F)
7 M F 8 1 2 4 -
FOUNDATION Fieldbus (FF)
F)
7 M F 8 1 2 5 -
7 7 7 7 7
-
7 7 7 7
© Siemens AG 2008