beautypg.com

Sitrans p measuring instruments for pressure – Siemens SITRANS P User Manual

Page 40

background image

SITRANS P measuring instruments for pressure

Transmitters for food, pharmaceuticals and biotechnology

SITRANS P300 for gage and absolute pressure

2/40

Siemens FI 01 · 2009

2

F) Subject to export regulations AL: 9I999, ECCN: N.

Selection and Ordering data

Order No.

SITRANS P300 pressure transmitters for gage
and absolute pressure with front-flush membrane
,
single-chamber measuring housing, rating plate
inscription in English

4 ... 20 mA/HART

F)

7 M F 8 1 2 3 -

PROFIBUS PA

F)

7 M F 8 1 2 4 -

FOUNDATION Fieldbus (FF)

F)

7 M F 8 1 2 5 -

7 7 7 7 7

-

7 7 7 7

Measuring cell filling

Measuring cell cleaning

Silicone oil

Standard

1

Inert liquid

Cleanliness level 2 to
DIN 25410

3

FDA compliant fill fluid
• Neobee oil

Standard

4

max. span
0.01 ... 1 bar g

(0.15 ... 14.5 psi g)

B

0.04 ... 4 bar g

(0.58 ... 58 psi g)

C

0.16 ... 16 bar g

(2.32 ... 232 psi g)

D

0.63 ... 63 bar g

(9.14 ... 914 psi g)

E

13 ... 1300 mbar a

1)

(0.19 ... 18.9 psi a)

S

0.05 ... 5 bar a

1)

(0.7 ... 72.5 psi a)

T

0.03 ... 30 bar a

1)

(4.35 ... 435 psi a)

U

Wetted parts materials

Seal diaphragm

Measuring cell

Stainless steel

Stainless steel

A

Process connection
• Flange version with Order code M.., N.., R.. or Q..

(see "Further designs")

7

Non-wetted parts materials
• Stainless steel, deep-drawn and electrolytically

polished

4

Version
• Standard version

1

Explosion protection
• Without

A

• With ATEX, Type of protection:

- "Intrinsic safety (EEx ia)"

B

• Zone 20/21/22

2)

C

• Ex nA/nL (zone 2)

3)

E

• With FM „Intrinsic safe“ (cFM

US

)

M

Electrical connection / cable entry
• Screwed gland M20x1.5 (Polyamide)

4)

A

• Screwed gland M20x1.5 (metal)

B

• Screwed gland M20x1.5 (stainless steel)

C

• M12 connector (without cable socket)

F

• M12 connector (stainless steel, without cable socket)

G

• ½-14 NPT thread, metal

5)

H

• ½-14 NPT thread, stainless steel

5)

J

Display
• Without display, with keys, closed lid

4)

1

• With display and keys, closed lid

2

• With display and keys, lid with macrolon washer

(setting on HART devices: mA,
on PROFIBUS PA and FOUNDATION Fieldbus
devices: pressure units)

4

• With display (setting acc. to specifications, Order

code "Y21" or "Y22" required), lid with macrolon
washer

5

• With display and keys, lid with glass pane

(setting on HART devices: mA,
on PROFIBUS PA and FOUNDATION Fieldbus
devices: pressure units)

6

• With display (setting acc. to specifications, Order

code "Y21" or "Y22" required), lid with glass pane

7

Power supply units

see "SITRANS I power supply units and isol. amplifiers".

Included in delivery of the device:
• Brief instructions (Leporello)
• CD-ROM with detailed documentation

1)

Not with temperature decoupler P00 and P10, not for process connections
R02, R04, R10 and R11, and can only be ordered in conjunction with sili-
cone oil.

2)

Can only be ordered in conjunction with electrical connection Option A.

3)

Can only be ordered in conjunction with electrical connection Option B, C,
F or G.

4)

Only together with HART electronics.

5)

Without cable gland.

Selection and Ordering data

Order No.

SITRANS P300 pressure transmitters for gage
and absolute pressure with front-flush membrane
,
single-chamber measuring housing, rating plate
inscription in English

4 ... 20 mA/HART

F)

7 M F 8 1 2 3 -

PROFIBUS PA

F)

7 M F 8 1 2 4 -

FOUNDATION Fieldbus (FF)

F)

7 M F 8 1 2 5 -

7 7 7 7 7

-

7 7 7 7

© Siemens AG 2008