Sitrans p measuring instruments for pressure, Diaphragm seals of flange design – Siemens SITRANS P User Manual
Page 164
SITRANS P measuring instruments for pressure
Diaphragm seals of flange design
For gage and absolute pressure,
directly fitted on transmitter
2/164
Siemens FI 01 · 2009
2
■
Overview
Diaphragm seals of flange design, directly fitted on a pressure transmitter
for pressure
■
Technical specifications
Diaphragm seals (flange design) for pressure and absolute pres-
sure, directly fitted on a transmitter
Nominal diameter
Nominal pressure
• DN 50
PN 40, PN 100
• DN 80
PN 40, PN 100
• DN 100
PN 16, PN 40
• 2 inch
Class 150, class 300, class 600,
class 1500
• 3 inch
Class 150, class 300, class 600
• 4 inch
Class 150, class 300, class 400
Sealing face
• For stainless steel, mat. No.
1.4404/316L
To EN 1092-1, form B1 or ASME
B16.5 RF 125 ... 250 AA
• For the other materials
Smooth to EN 1092-1, form B2 or
ASME B16.5 RFSF
Materials
• Main body
Stainless steel 316L
• Wetted parts
Stainless steel 316L
• Without foil
• PTFE (for vacuum on request)
• ECTFE (for vacuum on request)
• PFA (for vacuum on request)
Monel 400, mat. No. 2.4360
Hastelloy C276, mat. No. 2.4819
Hastelloy C4, mat. No. 2.4610
Tantalum
• Capillary
Stainless steel, 1.4571/316Ti
• Sealing material on the process
connection
Copper
Maximum pressure
See above and the technical data
of the transmitter
Tube length
• Without tube
• 50 mm (1.97 inch)
• 100 mm (3.94 inch)
• 150 mm (5.91 inch)
• 200 mm (7.87 inch)
Capillary
• Length
Max. 10 m (32.8 ft), longer
lengths on request
• Internal diameter
2 mm (0.079 inch)
• Minimum bending radius
150 mm (5.9 inch)
Filling liquid
• Silicone oil M5
• Silicone oil M50
• High-temperature oil
• Halocarbon oil (for measuring
O
2
)
• Food oil (FDA listed)
• Glycerine/water (not suitable for
use in low-pressure range)
Max. recommended process
temperature
170 °C (338 °F)
Permissible ambient temperature
Dependent on the pressure trans-
mitter and the filling liquid of the
remote seal.
More information can be found in
the technical data of the pressure
transmitters and in the section
"Technical data of filling liquid" in
the Technical description to the
remote seals.
Weight
Approx. 4 kg (8.82 lb)
Certificate and approvals
Classification according to pressure
equipment directive (DRGL
97/23/EC)
For gases of fluid group 1 and liq-
uids of fluid group 1; complies
with requirements of article 3,
paragraph 3 (sound engineering
practice)
© Siemens AG 2008