beautypg.com

Sitrans p measuring instruments for pressure, Ds iii series with pmc connection 2/55 – Siemens SITRANS P User Manual

Page 55

background image

SITRANS P measuring instruments for pressure

Transmitters for gage pressure for the paper industry

DS III series with PMC connection

2/55

Siemens FI 01 · 2009

2

Selection and Ordering data

Order No.

SITRANS P pressure transmitters for gage
pressure, with PMC connection
series DS III HART

7 M F 4 1 3 3 -

7 7 7 7 7

-

7 7 7 7

Measuring cell filling

Measuring cell
cleaning

Silicone oil

Standard

1

Inert liquid

Grease-free

3

Span
0.01 ... 1 bar g

1)

1)

Only with "PMC Style Standard" process connection

(0.15 ... 14.5 psi g)

1)

B

0.04 ... 4 bar g

(0.58 ... 58 psi g)

C

0.16 ... 16 bar g

(2.32 ... 232 psi g)

D

Wetted parts materials
Seal diaphragm

Connection shank

Hastelloy

Stainless steel

B

Process connection
• PMC Style Standard: Thread 1½"

2

• PMC Style Mini bolt: 1" front-flush (min. span:

500 mbar (7.25 psi), can not be ordered with mit
1-bar (14.5 psi) measuring cell (Option B))

3

Non-wetted parts materials
• Housing made of die-cast aluminum

0

• Housing stainless steel precision casting

3

Version
• Standard version

1

• International version, English label inscriptions,

documentation in 5 languages on CD

2

Explosion protection
• None

A

Electrical connection / cable entry
• Female thread M20x1.5

B

• Female thread ½-14 NPT

C

• M12 connectors (metal)

F

Display
• Without indicator

0

• Without visible digital indicator (digital indicator

hidden, setting: mA)

}

1

• With visible digital indication, setting: mA

6

• With customer-specific digital indication (setting

as specified, Order code "Y21" or "Y22"
required)

7

Power supply units

see "SITRANS I power supply units and isolation

amplifiers".

Included in delivery of the device:
• Brief instructions (Leporello)
• CD-ROM with detailed documentation
• Sealing ring

Selection and Ordering data

Order No.

SITRANS P pressure transmitter for gage
pressure, with PMC connection

DS III PA (PROFIBUS PA) series

7 M F 4 1 3 4 -

DS III FF series (FOUNDATION Fieldbus)

7 M F 4 1 3 5 -

7 7 7 7 7

-

7 7 7 7

Measuring cell filling

Measuring cell
cleaning

Silicone oil

Standard

1

Inert liquid

Grease-free

3

Nominal measuring range
1 bar g

1)

1)

Only with "PMC Style Standard" process connection

(14.5 psi g)

1)

B

4 bar g

(58 psi g)

C

16 bar g

(232 psi g)

D

Wetted parts materials
Seal diaphragm

Connection shank

Hastelloy

Stainless steel

B

Process connection
• PMC Style Standard: front-flush 1½"

2

• PMC Style Mini bolt: front-flush 1"

(min. span: 500 mbar (7.25 psi), can not be or-
dered with mit 1-bar (14.5 psi) measuring cell
(Option B))

3

Non-wetted parts materials
• Housing made of die-cast aluminum

0

• Housing stainless steel precision casting

3

Version
• Standard version

1

• International version, English label inscriptions,

documentation in 5 languages on CD

2

Explosion protection
• None

A

Electrical connection / cable inlet
• Screwed gland M20x1.5

B

• Screwed gland ½-14 NPT

C

• M12 connectors (metal)

F

Display
• Without indicator

0

• Without visible digital indicator (digital indicator

hidden, setting: mA)

}

1

• With visible digital display

6

• With customer-specific digital display (setting as

specified, Order code "Y21" or required)

7

Included in delivery of the device:
• Brief instructions (Leporello)
• CD-ROM with detailed documentation
• Sealing ring

© Siemens AG 2008