Sitrans p measuring instruments for pressure – Siemens SITRANS P User Manual

Page 114

background image

SITRANS P measuring instruments for pressure

Transmitters for gage, absolute and differential pressure, flow and level

DS III series
for differential pressure and flow

2/114

Siemens FI 01 · 2009

2

Selection and Ordering data

Order code

Further designs

Add "-Z" to Order No. and specify Order code.

HART PA

FF

Pressure transmitter with mounting
bracket made of:
• Steel

A01

9

9

9

9

9

9

• Stainless steel

A02

9

9

9

9

9

9

O-rings for process flanges
(instead of FPM (Viton))
• PTFE (Teflon)

A20

9

9

9

9

9

9

• FEP (with silicone core, approved for food)

A21

9

9

9

9

9

9

• FFPM (Kalrez, compound 4079)

A22

9

9

9

9

9

9

• NBR (Buna N)

A23

9

9

9

9

9

9

Plug
• Han 7D (metal, gray)

A30

9

9

• Han 8U (instead of Han 7D)

A31

9

9

Sealing screws
¼-18 NPT, with valve in mat. of process flanges

A40

9

9

9

9

9

9

Cable sockets for M12 connectors (metal)

A50

9

9

9

9

9

9

Rating plate inscription (instead of German)
• English

B11

9

9

9

9

9

9

• French

B12

9

9

9

9

9

9

• Spanish

B13

9

9

9

9

9

9

• Italian

B14

9

9

9

9

9

9

English rating plate (calibration certificate) B21

9

9

9

9

9

9

Pressure units in inH

2

O or psi

Quality inspection certificate (Factory cali-
bration) to IEC 60770-2

1)

C11

9

9

9

9

9

9

Acceptance test certificate

2)

To EN 10 204-3.1

C12

9

9

9

9

9

9

Factory certificate
To EN 10 204-2.2

C14

9

9

9

9

9

9

"Functional Safety (SIL)" certificate

C20

9

9

"PROFIsafe" certificate and protocol

C21

9

9

Setting of upper limit of output signal to
22.0 mA

D05

9

9

Manufacturer's declaration acc. to NACE

D07

9

9

9

9

9

9

(only together with seal diaphragm made of
Hastelloy and stainless steel)

Type of protection IP68
(not together with 7D/
Han 8U plug, cable gland Pg 13.5)

D12

9

9

9

9

9

9

Digital indicator alongside the input keys

D27

9

9

9

9

9

9

(only together with the devices 7MF4433-
....2-.A.6 or -.A.7-Z, Y21 or Y22 + Y01)

Process flange screws made of Monel
(max. nominal pressure PN20)

D34

9

9

9

9

9

9

Supplied with oval flange set

D37

9

9

9

9

9

9

(2 items), PTFE packings and stainles steel
screws in thread of process flanges

Use in or on zone 1D/2D

E01

9

9

9

9

9

9

(only together with type of protection
"Intrinsic safety (EEx ia)")

Use on zone 0

E02

9

9

9

9

9

9

(only together with type of protection
"Intrinsic safety (EEx ia)")

TÜV approval to AD/TRD

E06

9

9

(only together with type of protection
"Intrinsic safety (EEx ia)")

Overfilling safety device for flammable
and non-flammable liquids
(max. PN 32 (MVWP 464 psi), basic device
with type of protection "Intrinsic safety
(EEx ia)", to WHG and VbF, not together with
measuring cell filling "inert liquid")

E08

9

9

9

9

9

9

Oxygen application

E10

9

9

9

9

9

9

(max. 120 bar (1740 psi) at 60°C (140 °F) with
oxygen measurement and inert liquid)

Explosion-proof "Intrinsic safety" to
INMETRO (Brazil)

E25

9

9

9

9

9

9

(only for transmitter 7MF4...-.....-.B..)

Explosion-proof "Intrinsic safety" to NEPSI
(China)

E55

9

9

9

9

9

9

(only for transmitter 7MF4...-.....-.B..)

Explosion protection "Explosion-proof" to
NEPSI (China)
(only for transmitter 7MF4...-.....-.D..)

E56

9

9

9

9

9

9

Explosion-proof "Zone 2" to NEPSI (China) E57

9

9

9

9

9

9

(only for transmitter 7MF4...-.....-.E..)

Interchanging of process connection side

H01

9

9

9

9

9

9

Vent on side for gas measurements

H02

9

9

9

9

9

9

Stainless steel process flanges for vertical
differential pressure lines
(not together with K01, K02 and K04)

3)

H03

9

9

9

9

9

9

Process flange
• Hastelloy

K01

9

9

9

9

9

9

• Monel

K02

9

9

9

9

9

9

• Stainless steel with PVDF insert

max. PN 10 (MWP 145 psi),
max. temperature of medium 90 °C (194 °F)

K04

9

9

9

9

9

9

For ½-14 NPT inner process connection on
the side in the middle of the process flange,
vent valve not possible

9

9 = available

1)

When the manufacture’s certificate M (calibration certificate) has to be
ordered for transmitters with diaphragm seals, it is recommended only to
order this certificate exclusively with the diaphragm seals. The measuring
accuracy of the total combination is certified here.

2)

Whe the acceptance test certificate 3.1 for transmitters with direct-con-
nected diaphragm seals is ordered, this certificate must also be ordered
with the corresponding seals.

3)

Not suitable for connection of remote seal

Selection and Ordering data

Order code

Further designs

Add "-Z" to Order No. and specify Order code.

HART PA

FF

© Siemens AG 2008