beautypg.com

Sitrans p measuring instruments for pressure, Diaphragm seals of flange design – Siemens SITRANS P User Manual

Page 169

background image

SITRANS P measuring instruments for pressure

Diaphragm seals of flange design

For differential pressure,

fixed connection and with capillary

2/169

Siemens FI 01 · 2009

2

Dimensional drawings

Diaphragm seals of flange design with flexible capillary, fixed connec-
tion, for connection to a SITRANS P pressure transmitter for differential
pressure, dimensions in mm (inch)

Connection to EN 1092-1

Connection to ASME B16.5

d: Inside diameter of gasket according to EN 1092-1 /
ASME B16.5

d

M

: Effective diaphragm diameter

D

+

b

f

n d 2

x

ø

k

M

d

ø

d 4

R

15

0 (5

.9)

>_

100

(3.94)

b

f

n d 2

x

ø

D

ø

k

ø

d 4

ø

d 5

L

Tube length L

see

Ordering data

Nom.
diam.

Nom.
press.

b

D

d

2

d

4

d

5

d

M

f

k

n

mm

mm

mm

mm

mm

mm

mm

mm

DN 80

PN 40 24

200

18

138

76

89

2

160

8

DN 100 PN 16 20

200

18

158

94

89

2

180

8

PN 40 24

235

22

162

94

89

2

190

8

Nom.
diam.

Nom.
press.

b

D

d

2

d

4

d

5

d

M

f

k

n

lb/
sq.in.

mm

mm

mm

mm

mm

mm

mm

mm

(inch) (inch)

(inch) (inch) (inch) (inch) (inch) (inch)

3 inch

150

24

190

20

127

76

89

1,6

152,5

4

(0.96)

(7.48)

(0.79) (5)

(3)

(3.50) (0.06) (6)

300

29

210

22

127

76

89

1,6

168,5

8

(1.14)

(8.27)

(0.87) (5)

(3)

(3.50) (0.06) (6.63)

4 inch

150

24

230

20

158

94

89

1,6

190,5

4

(0.95)

(9.06)

(0.79) (6.22) (3.69) (3.50) (0.06) (7)

300

32

255

22

158

94

89

1,6

200

8

(1.26)

(10.04) (0.87) (6.22) (3.69) (3.50) (0.06) (7.87)

© Siemens AG 2008