beautypg.com

Sitrans p measuring instruments for pressure, Transmitters for hydrostatic level, Mps series (submersible sensor) 2/148 – Siemens SITRANS P User Manual

Page 148

background image

SITRANS P measuring instruments for pressure

Transmitters for hydrostatic level

MPS series (submersible sensor)

2/148

Siemens FI 01 · 2009

2

C) Subject to export regulations AL: N, ECCN: EAR99.
D) Subject to export regulations AL: N, ECCN: EAR99H.

Dimensional drawings

SITRANS P pressure transmitters, MPS series, dimensions in mm (inch)

Junction box, dimensions in mm (inch)

Cable hanger, dimensions in mm (inch)

Selection and Ordering data

Order No.

SITRANS P pressure transmitters
for pressure, MPS series (submers-
ible sensor)

C)

7 M F 1 5 7 0 -

7 7

A 0

7 7 7 7

2-wire system

Note: Junction box and cable hanger
included in delivery

Cable material
PE

}

1

FEP

5

Measuring range Cable length L
0 ... 2 mH

2

O

10 m

}

C

0 ... 4 mH

2

O

10 m

}

D

0 ... 5 mH

2

O

25 m

}

B

0 ... 6 mH

2

O

25 m

}

E

0 ... 10 mH

2

O

25 m

}

F

0 ... 20 mH

2

O

25 m

}

G

0 ... 6 ftH

2

O

32 ft

K

0 ... 12 ftH

2

O

32 ft

L

0 ... 18 ftH

2

O

82 ft

M

0 ... 30 ftH

2

O

82 ft

N

0 ... 60 ftH

2

O

82 ft

P

Special measuring range/Special cable
length

1)

Specify measuring range and cable
length in plain text

1)

Special measuring ranges between 0 ... 1 mH

2

O (0 ... 3 ftH

2

O)

and 0 ... 200 mH

2

O (0 ... 656 ftH

2

O) and special cable lengths up to

1000 m (3281ft) are possible. With Ex versions the max.
special cable length is 50 m (150 ft). The length of free-hanging cable
should not exceed 375 m.

Z

J 1 Y

Explosion protection

• without

}

1

• with, type of protection "Intrinsic safe-

ty" (Ex II 1 G EEx ia IIC T4)

}

2

• With approval for drinking water to

WRAS and ACS

}

D)

6

Further designs

Order code

Quality inspection certificate (Factory
calibration) to IEC 60770-2, add "-Z" to
Order No. and Order code.

C11

Order No.

Quality inspection certificate (Factory
calibration) to IEC 60770-2 supplied
later, specify factory no. of transmitter
for this porpose.

7MF1564-8CC11

Accessories (as spare parts)

Junction box

7MF1570-8AA

for connecting the transmitter cable

Cable hanger

7MF1570-8AB

for mounting the pressure transmitter

}

Available ex stock

Power supply units

see "SITRANS I power supply units and input isola-

tors".

+ (brown)

- (blue)

Screen

Vent pipe

Protective cap

158 (6.2)

L

Ø

27 (1.

1

diam

.)

Cable sheath 8.3 (0.33) diam. (black or blue, PE/HFFR)

Flexible cable with 0.5 mm

2

(0.00078 inch

2

) cross-section

Vent pipe 1 (0.04) diam. (inner diameter)

Protective cap with 4 x 3 diam. (4 x 0.12 diam.) holes (black, PA)

Cable sheath

Strength

cord (white)

Venting
valve

57 (2.25)

Mounting
hole

50 (1.97)

79 (3.1)

30

(1.2)

94 (3.7)

65 (2.56)

M20x1.5

22

(0.87)

M20x1.5

22

(0.87)

30

(1.2)

© Siemens AG 2008