beautypg.com

Sitrans p measuring instruments for pressure – Siemens SITRANS P User Manual

Page 42

background image

SITRANS P measuring instruments for pressure

Transmitters for food, pharmaceuticals and biotechnology

SITRANS P300 for gage and absolute pressure

2/42

Siemens FI 01 · 2009

2

Sanitary process connection to
NEUMO Connect S flange connection
certified to 3A and EHEDG
• DN 50, PN 16

Q63

9

9

9

9

9

9

• DN 65, PN 10

Q64

9

9

9

9

9

9

• DN 80, PN 10

Q65

9

9

9

9

9

9

• DN 100, PN 10

Q66

9

9

9

9

9

9

• DN 2“, PN 16

Q72

9

9

9

9

9

9

• DN 2½“, PN 10

Q73

9

9

9

9

9

9

• DN 3“, PN 10

Q74

9

9

9

9

9

9

• DN 4“, PN 10

Q75

9

9

9

9

9

9

Aseptic threaded socket to DIN 11864-1
Form A
• DN 50, PN 25

N33

9

9

9

9

9

9

• DN 65, PN 25

N34

9

9

9

9

9

9

• DN 80, PN 25

N35

9

9

9

9

9

9

• DN 100, PN 25

N36

9

9

9

9

9

9

Aseptic flange with notch to DIN 11864-2
Form A
• DN 50, PN 16

N43

9

9

9

9

9

9

• DN 65, PN 16

N44

9

9

9

9

9

9

• DN 80, PN 16

N45

9

9

9

9

9

9

• DN 100, PN 16

N46

9

9

9

9

9

9

Aseptic flange with groove to DIN 11864-2
Form A
• DN 50, PN 16

N43 +
P11

9

9

9

9

9

9

• DN 65, PN 16

N44 +
P11

9

9

9

9

9

9

• DN 80, PN 16

N45 +
P11

9

9

9

9

9

9

• DN 100, PN 16

N46 +
P11

9

9

9

9

9

9

Aseptic clamp with groove to DIN 11864-3
Form A
• DN 50, PN 25

N53

9

9

9

9

9

9

• DN 65, PN 25

N54

9

9

9

9

9

9

• DN 80, PN 16

N55

9

9

9

9

9

9

• DN 100, PN 16

N56

9

9

9

9

9

9

1)

When the manufacture’s certificate M (calibration certificate) has to be
ordered for transmitters with diaphragm seals, it is recommended only to
order this certificate exclusively with the diaphragm seals. The measuring
accuracy of the total combination is certified here.

2)

Whe the acceptance test certificate 3.1 for transmitters with direct-con-
nected diaphragm seals is ordered, this certificate must also be ordered
with the corresponding seals.

3)

Special Viton seal included in delivery.

4)

Lower measuring limit -100 mbar g (1.45 psi g).

5)

The weldable socket can be ordered under accessories

6)

Certified to 3A.
The maximum temperatures of the medium depend on the respective cell
fillings.

7)

3A certification only if used in conjunction with 3A-compliant sealing rings.

Selection and Ordering data

Order code

Further designs

Add "-Z" to Order No. and specify Order
code.

HART PA

FF

Selection and Ordering data

Order code

Additional data

Add "-Z" to Order No. and specify Order
code.

HART PA

FF

Measuring range to be set

Y01

9

9

Specify in plain text V (max. 5 digits):
Y01: ... up to ... mbar, bar, kPa, MPa, psi

Measuring point number (TAG No.)

Y15

9

9

9

9

9

9

Max. 16 characters, specify in plain text:
Y15: ...........................................

Measuring point text

Y16

9

9

9

9

9

9

Max. 27 characters, specify in plain text:
Y16: ...........................................

Entry of HART TAG

Y17

9

9

Max. 8 characters, specify in plain text:
Y17: ...........................................

Setting of pressure indication in pressure
units

Y21

9

9

9

9

9

9

Specify in plain text (standard setting: mA):
Y21: mbar, bar, kPa, MPa, psi, ...
Note:
The following pressure units can be selected:

bar, mbar, mm H

2

O

*)

, inH

2

O

*)

, ftH

2

O

*)

,

mmHG, inHG, psi, Pa, kPa, MPa, g/cm

2

,

kg/cm

2

, Torr, ATM or %

*) ref. temperature 20 °C

Setting of pressure indicator in
non-pressure units

Y22 +
Y01

9

9

Specify in plain text:
Y22: ..... up to ..... l, m

3

, m, USg, ...

(specification of measuring range in pressure
units "Y01" is essential, unit with max. 5 char-
acters)

Preset bus address

Y25

9

9

9

9

possible between 1 ... 126)
Specify in plain text:
Y25: .....................

Only "Y01" and "Y21" can be factory preset

9

9 = available
Ordering example
Item line:

7MF8023-1DB24-1AB7-Z

B line:

A02 + Y01 + Y21

C line:

Y01: 1 ... 10 bar (14.5 ... 145 psi)

C line:

Y21: bar (psi)

© Siemens AG 2008