Sitrans p measuring instruments for pressure – Siemens SITRANS P User Manual
Page 42
SITRANS P measuring instruments for pressure
Transmitters for food, pharmaceuticals and biotechnology
SITRANS P300 for gage and absolute pressure
2/42
Siemens FI 01 · 2009
2
Sanitary process connection to
NEUMO Connect S flange connection
certified to 3A and EHEDG
• DN 50, PN 16
Q63
9
9
9
9
9
9
• DN 65, PN 10
Q64
9
9
9
9
9
9
• DN 80, PN 10
Q65
9
9
9
9
9
9
• DN 100, PN 10
Q66
9
9
9
9
9
9
• DN 2“, PN 16
Q72
9
9
9
9
9
9
• DN 2½“, PN 10
Q73
9
9
9
9
9
9
• DN 3“, PN 10
Q74
9
9
9
9
9
9
• DN 4“, PN 10
Q75
9
9
9
9
9
9
Aseptic threaded socket to DIN 11864-1
Form A
• DN 50, PN 25
N33
9
9
9
9
9
9
• DN 65, PN 25
N34
9
9
9
9
9
9
• DN 80, PN 25
N35
9
9
9
9
9
9
• DN 100, PN 25
N36
9
9
9
9
9
9
Aseptic flange with notch to DIN 11864-2
Form A
• DN 50, PN 16
N43
9
9
9
9
9
9
• DN 65, PN 16
N44
9
9
9
9
9
9
• DN 80, PN 16
N45
9
9
9
9
9
9
• DN 100, PN 16
N46
9
9
9
9
9
9
Aseptic flange with groove to DIN 11864-2
Form A
• DN 50, PN 16
N43 +
P11
9
9
9
9
9
9
• DN 65, PN 16
N44 +
P11
9
9
9
9
9
9
• DN 80, PN 16
N45 +
P11
9
9
9
9
9
9
• DN 100, PN 16
N46 +
P11
9
9
9
9
9
9
Aseptic clamp with groove to DIN 11864-3
Form A
• DN 50, PN 25
N53
9
9
9
9
9
9
• DN 65, PN 25
N54
9
9
9
9
9
9
• DN 80, PN 16
N55
9
9
9
9
9
9
• DN 100, PN 16
N56
9
9
9
9
9
9
1)
When the manufacture’s certificate M (calibration certificate) has to be
ordered for transmitters with diaphragm seals, it is recommended only to
order this certificate exclusively with the diaphragm seals. The measuring
accuracy of the total combination is certified here.
2)
Whe the acceptance test certificate 3.1 for transmitters with direct-con-
nected diaphragm seals is ordered, this certificate must also be ordered
with the corresponding seals.
3)
Special Viton seal included in delivery.
4)
Lower measuring limit -100 mbar g (1.45 psi g).
5)
The weldable socket can be ordered under accessories
6)
Certified to 3A.
The maximum temperatures of the medium depend on the respective cell
fillings.
7)
3A certification only if used in conjunction with 3A-compliant sealing rings.
Selection and Ordering data
Order code
Further designs
Add "-Z" to Order No. and specify Order
code.
HART PA
FF
Selection and Ordering data
Order code
Additional data
Add "-Z" to Order No. and specify Order
code.
HART PA
FF
Measuring range to be set
Y01
9
9
Specify in plain text V (max. 5 digits):
Y01: ... up to ... mbar, bar, kPa, MPa, psi
Measuring point number (TAG No.)
Y15
9
9
9
9
9
9
Max. 16 characters, specify in plain text:
Y15: ...........................................
Measuring point text
Y16
9
9
9
9
9
9
Max. 27 characters, specify in plain text:
Y16: ...........................................
Entry of HART TAG
Y17
9
9
Max. 8 characters, specify in plain text:
Y17: ...........................................
Setting of pressure indication in pressure
units
Y21
9
9
9
9
9
9
Specify in plain text (standard setting: mA):
Y21: mbar, bar, kPa, MPa, psi, ...
Note:
The following pressure units can be selected:
bar, mbar, mm H
2
O
*)
, inH
2
O
*)
, ftH
2
O
*)
,
mmHG, inHG, psi, Pa, kPa, MPa, g/cm
2
,
kg/cm
2
, Torr, ATM or %
*) ref. temperature 20 °C
Setting of pressure indicator in
non-pressure units
Y22 +
Y01
9
9
Specify in plain text:
Y22: ..... up to ..... l, m
3
, m, USg, ...
(specification of measuring range in pressure
units "Y01" is essential, unit with max. 5 char-
acters)
Preset bus address
Y25
9
9
9
9
possible between 1 ... 126)
Specify in plain text:
Y25: .....................
Only "Y01" and "Y21" can be factory preset
9
9 = available
Ordering example
Item line:
7MF8023-1DB24-1AB7-Z
B line:
A02 + Y01 + Y21
C line:
Y01: 1 ... 10 bar (14.5 ... 145 psi)
C line:
Y21: bar (psi)
© Siemens AG 2008