beautypg.com

Flushing rings, Sitrans p measuring instruments for pressure – Siemens SITRANS P User Manual

Page 174

background image

SITRANS P measuring instruments for pressure

Flushing rings

For diaphragm seals

2/174

Siemens FI 01 · 2009

2

Overview

Flushing ring

Flushing rings are required for flange-mounted and sandwich-
type remote seals (Order No. 7MF4900 ... 7MF4923) if the dan-
ger exists that the process conditions and the geometry of the
connection could cause the medium to form deposits or block-
ages.

The flushing ring is clamped between the process flange and
the remote seal.

Deposits can be flushed away from the diaphragm through the
holes in the side, or the pressure volume can be vented. Different
nominal diameters and forms permit adaptation to the respec-
tive process flange.

Process connection

For flanges to EN and ASME:
DN 50, 80, 100, 125; PN 16 ... 100 or
DN 2 inch, 3 inch, 4 inch, 5 inch; Class 150 ... 600

Standard design

Material: CrNi-Stahl, mat. No. 1.4404/316L
Sealing faces and flushing holes: See Selection and Ordering
data

Design

Installation example

Technical specifications

Dichtung

Spülring

Measuring

point flange

Flushing outlet

Remote seal flange

Gasket

Flushing inlet

Flushing ring

Flushing ring for remote seals of sandwich and flange design

Nominal diameter

Nominal pressure

• DN 50

PN 16 ... PN 100

• DN 80

PN 16 ... PN 100

• DN 100

PN 16 ... PN 100

• DN 125

PN 16 ... PN 100

• 2 inch

Class 150 ... class 600

• 3 inch

Class 150 ... class 600

• 4 inch

Class 150 ... class 600

• 5 inch

Class 150 ... class 600

Sealing face

• To EN 1092-1

Form B1

Form B2

Form D/Form D

Form C/Form C

Form C/Form C

Form E

Form F

• To ASME B16.5

RF 125 ... 250 AA

RFSF

RJT ring groove

Flushing holes (2 off), female
thread:

• G¼

• G½

• ¼-18 NPT

• ½-14 NPT

Material

Stainless steel 1.4404/316L

© Siemens AG 2008