beautypg.com

Sitrans p measuring instruments for pressure – Siemens SITRANS P User Manual

Page 117

background image

SITRANS P measuring instruments for pressure

Transmitters for gage, absolute and differential pressure, flow and level

DS III series

for differential pressure and flow

2/117

Siemens FI 01 · 2009

2

Selection and Ordering data

Order No.

SITRANS P pressure transmitters for differen-
tial pressure and flow, Series DS III HART
PN 420 (MWP 6092 psi)

DS III PA (PROFIBUS PA) series

7 M F 4 5 3 4 -

DS III FF series (FOUNDATION Fieldbus)

7 M F 4 5 3 5 -

1

7 7 7 7

-

7 7 7 7

Nominal measuring range
250 mbar

(100.4 inH

2

O)

D

600 mbar

(240.9 inH

2

O)

E

1600 mbar

(642.4 inH

2

O)

F

5 bar

(2008 inH

2

O)

G

30 bar

(435 psi)

H

Wetted parts materials
(stainless steel process flanges)
Seal diaphragm

Parts of measuring cell

Stainless steel

Stainless steel

A

Hastelloy

Stainless steel

B

Gold

1)

Gold

L

Process connection
Female thread ¼-18 NPT with flange connection
• Sealing screw opposite process connection

- Mounting thread

7

/

16

-20 UNF to EN 61518

3

- Mounting thread M12 to DIN 19213

(only for replacement needs)

1

• Venting on side of process flanges. Position of

the top vent valve in the process flanges (see
dimensional drawing).
- Mounting thread

7

/

16

-20 UNF to EN 61518

7

- Mounting thread M12 to DIN 19213

(only for replacement needs)

5

Non-wetted parts materials
Process flange screws

Electronics housing

Stainless steel

Die-cast aluminium

2

Stainless steel

Stainless steel precision
casting

3

Version
• Standard version

1

• International version, English label inscriptions,

documentation in 5 languages on CD

2

Explosion protection
• Without

A

• With ATEX, Type of protection:

- "Intrinsic safety (EEx ia)"

B

- "Explosion-proof (EEx d)"

2)

D

- "Intrinsic safety and explosion-proof

enclosure (EEx ia + EEx d)"

3)

P

- "Ex nA/nL (zone 2)"

E

- "Intrinsic safety, explosion-proof enclosure

and dust explosion protection (EEx ia +
EEx d + Zone 1D/2D)"

3)

(not for DS III FF)

R

• With FM + CSA, Type of protection:

- "Intrinsic safety and explosion-proof

(is + xp)"

2)

, max PN 360

N C

Electrical connection / cable entry
• Screwed gland M20x1.5

B

• Screwed gland ½-14 NPT

C

• Plug M12 incl. mating connector

4)

F

Display
• Without indicator

0

• Without visible digital indicator (digital indicator

hidden, setting: mA)

}

1

• With visible digital indicator

6

• With customer-specific digital indicator (setting

as specified, Order code "Y21" or required)

7

Factory-mounting of shut-off valves and valve manifolds see page
2/142.

Included in delivery of the device:
• Brief instructions (Leporello)
• CD-ROM with detailed documentation
• Sealing plug(s) or sealing screw(s) for the process flanges(s)

1)

Not together with max. span 600 mbar (240.9 inH

2

O)

2)

Without cable gland, with blanking plug.

3)

With enclosed cable gland EEx ia and blanking plug.

4)

Not together with types of protection "Explosion-proof" and "Intrinsic safety
and explosion-proof"

Selection and Ordering data

Order No.

SITRANS P pressure transmitters for differen-
tial pressure and flow, Series DS III HART
PN 420 (MWP 6092 psi)

DS III PA (PROFIBUS PA) series

7 M F 4 5 3 4 -

DS III FF series (FOUNDATION Fieldbus)

7 M F 4 5 3 5 -

1

7 7 7 7

-

7 7 7 7

© Siemens AG 2008