SITRANS P measuring instruments for pressure

Diaphragm seals of flange design

For differential pressure,

fixed connection and with capillary

2/167

Siemens FI 01 · 2009

2

Overview

Diaphragm seals of flange design for pressure transmitters for differential
pressure, fixed connection and with flexible capillary

Technical specifications

Diaphragm seals of flange design for pressure transmitters for dif-
ferential pressure, fixed connection and with flexible capillary

Nominal diameter

Nominal pressure

• DN 80

PN 40

• DN 100

PN 16, PN 40

• 3 inch

Class 150, class 300

• 4 inch

Class 150, class 300

Sealing face

• For stainless steel, mat.

No. 1.4404/316L

To EN 1092-1, form B1 or

ASME B16.5 RF 125 ... 250 AA

• For the other materials

To EN 1092-1, form B2 or

ASME B16.5 RFSF

Materials

• Main body

Stainless steel 316L

• Wetted parts

Stainless steel 316L

• Without foil

• PTFE (for vacuum on request)

• ECTFE (for vacuum on request)

• PFA (for vacuum on request)

Monel 400, mat. No. 2.4360

Hastelloy C276, mat. No. 2.4819

Hastelloy C4, mat. No. 2.4610

Tantalum

• Capillary

Stainless steel, mat.
No. 1.4571/316Ti

• Sheath

Spiral hose made of stainless
steel, mat. No. 1.4301/316

Sealing material in the process
flanges

• For pressure transmitters, absolute

pressure transmitters and low-
pressure applications

Copper

• For other applications

Viton

Maximum pressure

See above and the technical data
of the pressure transmitter

Tube length

Without tube

50 mm (1.97 inch)

100 mm (3.94 inch)

150 mm (5.91 inch)

200 mm (7.87 inch)

Capillary

• Length

Max. 10 m (32.8 ft), longer
lengths on request

• Internal diameter

2 mm (0.079 inch)

• Minimum bending radius

150 mm (5.9 inch)

Filling liquid

Silicone oil M5

Silicone oil M50

High-temperature oil

Halocarbon oil (for measuring O

2

)

Food oil (FDA listed)

Glycerine/water (not suitable for
use in low-pressure range)

Max. recommended process
temperature

170 °C (338 °F)

Permissible ambient temperature

Dependent on the pressure trans-
mitter and the filling liquid of the
remote seal

More information can be found in
the technical data of the pressure
transmitters and in the section
"Technical data of filling liquid" in
the Technical description to the
remote seals

Weight

Approx. 4 kg (8.82 lb)

Certificate and approvals

Classification according to pressure
equipment directive (DRGL
97/23/EC)

For gases of fluid group 1 and liq-
uids of fluid group 1; complies
with requirements of article 3,
paragraph 3 (sound engineering
practice)