Sitrans p measuring instruments for pressure – Siemens SITRANS P User Manual
Page 85
SITRANS P measuring instruments for pressure
Transmitters for gage, absolute and differential pressure, flow and level
DS III series for gage and absolute pressure,
with front-flush diaphragm
2/85
Siemens FI 01 · 2009
2
Sanitary process connection to NEUMO
Connect S flange connection
certified to EHEDG
• DN 50, PN 16
Q63
9
9
9
9
9
9
• DN 65, PN 10
Q64
9
9
9
9
9
9
• DN 80, PN 10
Q65
9
9
9
9
9
9
• DN 100, PN 10
Q66
9
9
9
9
9
9
• DN 2“, PN 16
Q72
9
9
9
9
9
9
• DN 2½“, PN 10
Q73
9
9
9
9
9
9
• DN 3“, PN 10
Q74
9
9
9
9
9
9
• DN 4“, PN 10
Q75
9
9
9
9
9
9
Aseptic threaded socket to DIN 11864-1
Form A
• DN 50, PN 25
N33
9
9
9
9
9
9
• DN 65, PN 25
N34
9
9
9
9
9
9
• DN 80, PN 25
N35
9
9
9
9
9
9
• DN 100, PN 25
N36
9
9
9
9
9
9
Aseptic flange with notch to DIN 11864-2
Form A
• DN 50, PN 16
N43
9
9
9
9
9
9
• DN 65, PN 16
N44
9
9
9
9
9
9
• DN 80, PN 16
N45
9
9
9
9
9
9
• DN 100, PN 16
N46
9
9
9
9
9
9
Aseptic flange with groove to DIN 11864-2
Form A
• DN 50, PN 16
N43 +
P11
9
9
9
9
9
9
• DN 65, PN 16
N44 +
P11
9
9
9
9
9
9
• DN 80, PN 16
N45 +
P11
9
9
9
9
9
9
• DN 100, PN 16
N46 +
P11
9
9
9
9
9
9
Aseptic clamp with groove to DIN 11864-3
Form A
• DN 50, PN 25
N53
9
9
9
9
9
9
• DN 65, PN 25
N54
9
9
9
9
9
9
• DN 80, PN 16
N55
9
9
9
9
9
9
• DN 100, PN 16
N56
9
9
9
9
9
9
1)
Special Viton seal included in delivery.
2)
Lower measuring limit -100 mbar g (1.45 psi g).
3)
The weldable socket can be ordered under accessories
4)
The maximum temperatures of the medium depend on the respective cell
fillings.
Selection and Ordering data
Order code
Further designs
HART PA
FF
Add "-Z" to Order No. and specify Order
code.
Selection and Ordering data
Order code
Additional data
HART PA
FF
Add "-Z" to Order No. and specify Order
code.
Measuring range to be set
Y01
9
9
Specify in plain text (max. 5 digits):
Y01: ... up to ... mbar, bar, kPa, MPa, psi
Measuring point number (TAG No.)
Y15
9
9
9
9
9
9
Max. 16 characters, specify in plain text:
Y15: ...........................................
Measuring point text
Y16
9
9
9
9
9
9
Max. 27 characters, specify in plain text:
Y16: ...........................................
Setting of pressure indicator in pressure
units
Y21
9
9
9
9
9
9
Specify in plain text (standard setting: mA):
Y21: mbar, bar, kPa, MPa, psi, ...
Note:
The following pressure units can be selected:
bar, mbar, mm H
2
O
*)
, inH
2
O
*)
, ftH
2
O
*)
,
mmHG, inHG, psi, Pa, kPa, MPa, g/cm
2
,
kg/cm
2
, Torr, ATM oder %
*) ref. temperature 20 °C
Preset bus address
Y25
9
9
(possible between 1 and 126)
Specify in plain text:
Y25: .....................
Only "Y01" and "Y21" can be factory preset
9
9 = available
Ordering example
Item line:
7MF4133-1DB20-1AB7-Z
B line:
A22 + Y01 + Y21
C line:
Y01: 1 ... 10 bar (14.5 ... 145 psi)
C line:
Y21: bar (psi)
© Siemens AG 2008