Sitrans p measuring instruments for pressure – Siemens SITRANS P User Manual
Page 39
SITRANS P measuring instruments for pressure
Transmitters for food, pharmaceuticals and biotechnology
SITRANS P300 for gage and absolute pressure
2/39
Siemens FI 01 · 2009
2
F) Subject to export regulations AL: 9I999, ECCN: N.
Selection and Ordering data
Order No.
SITRANS P300 pressure transmitters for gage
and absolute pressure, single-chamber measur-
ing housing, rating plate inscription in English
4 ... 20 mA/HART
7 M F 8 0 2 3 -
PROFIBUS PA
7 M F 8 0 2 4 -
FOUNDATION Fieldbus (FF)
7 M F 8 0 2 5 -
7 7 7 7 7
-
7 7 7 7
Measuring cell filling
Measuring cell cleaning
Silicone oil
Standard
1
Inert liquid
Cleanliness level 2 to
DIN 25410
3
max. span
0.01 ... 1 bar g
(0.145 ... 14.5 psi g)
B
0.04 ... 4 bar g
(0.58 ... 58 psi g)
C
0.16 ...16 bar g
(2.32 ... 232 psi g)
D
0.63 ... 63 bar g
(9.14 ... 914 psi g)
E
1.6 ... 160 bar g
(23.2 ... 2320 psi g)
F
4 ... 400 bar g
(58 ... 5800 psi g)
G
2.5 ... 25 mbar a
(0.036 ... 3.63 psi a)
F)
Q
13 ... 1300 mbar a
(0.19 ... 18.9 psi a)
F)
S
0.05 ... 5 bar a
(0.7 ... 72.5 psi a)
F)
T
0.3 ... 30 bar a
(4.35 ... 435 psi a)
F)
U
Wetted parts materials
Seal diaphragm
Measuring cell
Stainless steel
Stainless steel
A
Hastelloy
Stainless steel
F)
B
Hastelloy
Hastelloy
F)
C
Version for diaphragm seal
1)
2)
Y
Process connection
• G½B to EN 837-1
0
• ½-14 NPT
1
• Oval flange made of stainless steel
- Mounting thread
7
/
16
-20 UNF to EN 61518
2
- Mounting thread M10 to DIN 19213
3
- Mounting thread M12 to DIN 19213
4
• Male thread M20 x 1,5
5
• Male thread ½ -14 NPT
6
Non-wetted parts materials
• St. steel, deep-drawn and electrolytically polished
4
Version
• Standard version
1
Explosion protection
• Without
A
• With ATEX, Type of protection:
- "Intrinsic safety (EEx ia)"
B
• Zone 20/21/22
3)
C
• Ex nA/nL (zone 2)
4)
E
• With FM „Intrinsic safe“ (cFM
US
)
M
Electrical connection / cable entry
• Screwed gland M20x1.5 (Polyamide)
5)
A
• Screwed gland M20x1.5 (metal)
B
• Screwed gland M20x1.5 (stainless steel)
C
• M12 connector (metal, without cable socket)
F
• M12 connector (stainless steel, without cable socket)
G
• ½-14 NPT thread, metal
6)
H
• ½-14 NPT thread, stainless steel
6)
J
Display
• Without display, with keys, closed lid
5)
1
• With display and keys, closed lid
2
• With display and keys, lid with macrolon washer
(setting on HART devices: mA,
on PROFIBUS PA and FOUNDATION Fieldbus
devices: pressure units)
4
• With display (setting acc. to specifications, Order
code "Y21" or "Y22" required), lid with macrolon
washer
5
• With display and keys, lid with glass pane
(setting on HART devices: mA, on PROFIBUS and
FOUNDATION Fieldbus devices: pressure units)
6
• With display (setting acc. to specifications, Order
code "Y21" or "Y22" required), lid with glass pane
7
Power supply units
see "SITRANS I power supply units and isol. amplifiers".
Factory-mounting of shut-off valves and valve manifolds see page
2/142.
Included in delivery of the device:
• Brief instructions (Leporello)
• CD-ROM with detailed documentation
1)
When the manufacture’s certificate M (calibration certificate) has to be
ordered for transmitters with diaphragm seals, it is recommended only to
order this certificate exclusively with the diaphragm seals. The measuring
accuracy of the total combination is certified here.
2)
Whe the acceptance test certificate 3.1 for transmitters with direct-con-
nected diaphragm seals is ordered, this certificate must also be ordered
with the corresponding seals.
3)
Can only be ordered in conjunction with electrical connection Option A.
4)
Can only be ordered in conjunction with electrical connection Option B, C,
F or G.
5)
Only together with HART electronics.
6)
Without cable gland.
Selection and Ordering data
Order No.
SITRANS P300 pressure transmitters for gage
and absolute pressure, single-chamber measur-
ing housing, rating plate inscription in English
4 ... 20 mA/HART
7 M F 8 0 2 3 -
PROFIBUS PA
7 M F 8 0 2 4 -
FOUNDATION Fieldbus (FF)
7 M F 8 0 2 5 -
7 7 7 7 7
-
7 7 7 7
© Siemens AG 2008