beautypg.com

Sitrans p measuring instruments for pressure, Clamp-on seals of flange design – Siemens SITRANS P User Manual

Page 177

background image

SITRANS P measuring instruments for pressure

Clamp-on seals of flange design

For gage pressure, differential pressure and flow

2/177

Siemens FI 01 · 2009

2

D) Subject to export regulations AL: N, ECCN: EAR99H.

Selection and Ordering data

Order No. Ord. code

Clamp-on seal for flange-mounting for
SITRANS P pressure transmitters

for pressure
7MF403

7

and 7MF423

7

together with Order

code "V01" (vacuum-proof design) and
7MF802

7

1)

; must be ordered separately, scope

of delivery: 1 off

1)

With 7MF802

7

and the measuring cells Q, S, T and U also order the

vacuum-tight version.

D)

7 M F 4 9 8 0 -

for differential pressure and flow
7MF4433 or 7MF4434; order separately, scope
of delivery: 1 pair (set); Material: Completely of
stainless steel, mat. No. 1.4404/316L;
Process connection to EN 1092-1 or ASME
B16.5; sealing face to EN 1092-1, form B1,
or to ASME B16.5 RF 125 ... 250 AA

D)

7 M F 4 9 8 3 -

1

7 7

0

7

-

7

B

7 7 7

Nominal diameter and nominal pressure
• DN 25

PN 6 ... 100

B

• DN 40

PN 6 ... 100

D

• DN 50

PN 6 ... 100

E

• DN 80

PN 6 ... 100

G

• DN 100

PN 6 ... 100

H

• 1 inch

Class 150 ... 2500

L

• 1½ inch

Class 150 ... 2500

M

• 2 inch

Class 150 ... 2500

N

• 3 inch

Class 150 ... 2500

P

• 4 inch

Class 150 ... 2500

Q

Other version
Add Order code and plain text:
Nominal diameter: ...; Nominal pressure: ...

Z

J 1 Y

Wetted parts materials
• Stainless steel 316L

- Without foil

A

- With PFA coating

D

- With ECTFE coating

2)

2)

For vacuum on request.

F

• Monel 400, mat. No. 2.4360

G

• Hastelloy C276, mat. No. 2.4819

J

• Hastelloy C4, mat. No. 2.4610

U

• Tantalum

K

Other version
Add Order code and plain text:
Wetted parts materials: ...

Z

K 1 Y

Filling liquid
• Silicone oil M5

1

• Silicone oil M50

2

• High-temperature oil

3

• Halocarbon oil (for measuring O

2

)

4

• Glycerin/water

3)

3)

Not suitable for use in low-pressure range.

6

• Food oil (FDA listed)

7

Other version
Add Order code and plain text:
Filling liquid: ...

9

M 1 Y

Connection to transmitter
• direct (only for 7MF4980)

0

through capillary, length:

4)

4)

Max. capillary length, see section "Technical description"

• 1.0 m

(3.28 ft)

2

• 1.6 m

(5.25 ft)

3

• 2.5 m

(8.20 ft)

4

• 4.0 m

(13.1 ft)

5

• 6.0 m

(19.7 ft)

6

• 8.0 m

(26.25 ft)

7

• 10.0 m

(32.8 ft)

8

Other version
Add Order code and plain text:
Length of capillary: ...

9

N 1 Y

Selection and Ordering data

Order code

Further designs

Please add "-Z" to Order No. and specify Order code.

Spark arrestor
With spark arrestor for mounting on zone 0 (including
documentation)

• Pressure and absolute pressure

A01

• for differential pressure transmitters

A02

Quality inspection certificate (Factory calibration) to
IEC 60770-2

C11

Acceptance test certificate

C12

To EN 10204, section 3.1

Vacuum-proof design

V01

For use in low-pressure range

Calculation of span of associated pressure trans-
mitter

Y05

Enclose filled-in questionnaire with order
Note:
Suffix "Y01" required with pressure transmitter!

© Siemens AG 2008