beautypg.com

Sitrans p measuring instruments for pressure, Quick-release diaphragm seals, For gage, absolute and differential pressure 2/171 – Siemens SITRANS P User Manual

Page 171

background image

SITRANS P measuring instruments for pressure

Quick-release diaphragm seals

For gage, absolute and differential pressure

2/171

Siemens FI 01 · 2009

2

Selection and Ordering data

Order No. Ord. code

Quick-release diaphragm seal

D)

7 M F 4 9 4 0 -

for SITRANS P pressure transmitters for
pressure 7MF403

7

and 7MF423

7

together with

Order code "V01" (vacuum-proof design) and
7MF802

7

1)

; must be ordered separately

Filling liquid: Food oil (FDA listed)
Material: Stainless steel, mat. No. 1.4435

1)

With 7MF802

7

and the measuring cells Q, S, T and U also order the

vacuum-tight version.

7 7

A 0

7

-

7

B

7 7 7

Nom. diam.

Nom. press.

• Connection to DIN 11851 with slotted union nut

- DN 25

PN 40

1 B

- DN 32

PN 40

1 C

- DN 40

PN 40

1 D

- DN 50

PN 25

1 E

- DN 65

PN 25

1 F

- DN 80

PN 25

1 G

• Connection to DIN 11851 with screw necks

- DN 25

PN 40

2 B

- DN 32

PN 40

2 C

- DN 40

PN 40

2 D

- DN 50

PN 25

2 E

- DN 65

PN 25

2 F

- DN 80

PN 25

2 G

• Clamp connection

- 1½ inch

PN 40

4 L

- 2 inch

PN 40

4 M

- 2½ inch

PN 40

4 N

- 3 inch

PN 40

4 P

Other version
Add Order codes and plain text:
Nominal diameter: ...

9

H 1 Y

Nominal pressure: ...

Z

J 1 Y

Filling liquid
• Glycerin/water

2)

2)

Not suitable for use in low-pressure range.

6

• Food oil (FDA listed)

7

Other version
Add Order code and plain text:
Filling liquid: ...

9

M 1 Y

Connection to pressure transmitter
• direct

0

through capillary, length:

3)

3)

Max. capillary length, see section "Technical description"

D) Subject to export regulations AL: N, ECCN: EAR99H.

• 1.0 m

(3.28 ft)

2

• 1.6 m

(5.25 ft)

3

• 2.5 m

(8.20 ft)

4

• 4.0 m

(13.1 ft)

5

• 6.0 m

(19.7 ft)

6

• 8.0 m

(26.25 ft)

7

• 10.0 m

(32.8 ft)

8

Other version
Add Order code and plain text:
Length of capillary: ...

9

N 1 Y

Further designs

Order code

Please add "-Z" to Order No. and specify Order
code.

Quality inspection certificate (Factory cali-
bration) to IEC 60770-2

C11

Acceptance test certificate

C12

to EN 10204, section 3.1

Vacuum-proof design

V01

for use in low-pressure range

Selection and Ordering data

Order No. Ord. code

Quick-release diaphragm seal

D)

7 M F 4 9 4 3 -

for SITRANS P pressure transmitters for pres-
sure for differential pressure and flow, type
7MF443

7

; order separately

Filling liquid: Food oil (FDA listed)
Material: Stainless steel, mat. No. 1.4435
Delivery unit: 2 off

7 7

A 0

7

-

7

B

7 7 7

Nom. diam.

Nom. press.

• Connection to DIN 11851 with slotted union nut

- DN 50

PN 25

1 E

- DN 65

PN 25

1 F

- DN 80

PN 25

1 G

• Connection to DIN 11851 with threaded

socket
- DN 50

PN 25

2 E

- DN 65

PN 25

2 F

- DN 80

PN 25

2 G

• Clamp connection

- 2 inch

PN 40

4 M

- 2½ inch

PN 40

4 N

- 3 inch

PN 40

4 P

Other version
Add Order codes and plain text:
Nominal diameter: ...

9

H 1 Y

Nominal pressure: ...

Z

J 1 Y

Filling liquid
• Glycerin/water

1)

6

• Food oil (FDA listed)

7

Other version
Add Order code and plain text:
Filling liquid: ...

9

M 1 Y

Connection to transmitter

through capillary, Length:

2)

• 1.0 m

(3.28 ft)

2

• 1.6 m

(5.25 ft)

3

• 2.5 m

(8.20 ft)

4

• 4.0 m

(13.1 ft)

5

• 6.0 m

(19.7 ft)

6

• 8.0 m

(26.25 ft)

7

• 10.0 m

(32.8 ft)

8

Other version
Add Order code and plain text:
Length of capillary: ...

9

N 1 Y

Further designs

Order code

Please add "-Z" to Order No. and specify Order
code.

Quality inspection certificate (Factory cali-
bration) to IEC 60770-2

C11

Acceptance test certificate

C12

to EN 10204, section 3.1

Vacuum-proof design

V03

for use in low-pressure range

1)

Not suitable for use in low-pressure range.

2)

Max. capillary length, see section "Technical description"

D) Subject to export regulations AL: N, ECCN: EAR99H.

© Siemens AG 2008