beautypg.com

Ricoh PJ WU6181N 6200-Lumen WUXGA LCD Projector (No Lens) User Manual

Page 261

background image

246

10. Appendix

Lamp Indicator

Indicator display

Projector status

Procedure

Off

The lamp is turned off.

Flashing

Green

Preparing to relight lamp after
lighting has failed

Wait a while.

Red

Lamp replacement grace period

The lamp has reached the end of its service life and is now in
the replacement grace period (100 hours). Replace the lamp
as soon as possible. (

page

176

)

Red (cycles of 6) Lamp does not light

The lamp has not turned on. Wait at least 1 minute, then turn
the power back on. If the lamp still does not light, contact an
Ricoh projector customer support center.

Lit

Red

Lamp usage time exceeded

The lamp has exceeded its usage time. The projector’s power
cannot be turned on until the lamp is replaced. (

page

176

)

Green

Lamp lit

Temp. Indicator

Indicator display

Projector status

Procedure

Off

No problem

Flashing

Red (cycles of 2) Temperature problem

The temperature protector has been activated. If the room
temperature is high, move the projector to a cool place. If the
problem still persists, contact an Ricoh projector customer
support center.

Lit

Orange

High surrounding temperature

The surrounding temperature is high. Lower the room tem-
perature.

If the temperature protector is activated

If the projector’s internal temperature rises abnormally, the lamp turns off and the temperature indicator flashes (repeatedly in
cycles of 2).
It may happen that the projector’s temperature protector is simultaneously activated and the projector’s power turns off.
If this happens, do the following:

- Unplug the power cord from the power outlet.
- If using in a place where the surrounding temperature is high, move the projector to a different, cool place.
- If there is dust in the ventilation holes, clean. (

pages

171

and

174

)

- Wait as such about 1 hour for the projector’s internal temperature to lower.