3 speed control (analog voltage reference), 1 basic settings for speed control, 1) signal setting – Yaskawa Σ-V Series AC Servo Drives Rotational Motor Analog Voltage Reference User Manual
Page 97: Analog

5.3 Speed Control (Analog Voltage Reference)
5-17
5
Op
er
at
io
n
5.3
Speed Control (Analog Voltage Reference)
This section describes operation with speed control.
Select the speed control with parameter Pn000.1.
5.3.1
Basic Settings for Speed Control
This section describes the basic settings for speed control.
(1) Signal Setting
Input the speed reference to the SERVOPACK using the analog voltage reference to control the servomotor
speed in proportion to the input voltage.
Maximum input voltage: ±12 VDC
Input Circuit Example
Example:
Motor rated speed with Pn300 = 006.00: 6.00 V [Factory setting]
Note: The setting value is 600, but it will be displayed on the operator as 006.00.
Connect the pins for the V-REF signal and SG to the speed reference output terminal on the host controller
when using a host controller, such as a programmable controller, for position control.
Note: Always use twisted-pair cable to control noise.
Parameter
Meaning
When Enabled
Classification
Pn000
n.
0
[Factory setting]
Speed control (analog voltage reference)
After restart
Setup
Type
Signal Name
Connector
Pin Number
Name
Input
V-REF
CN1-1
Speed reference input
SG
CN1-2
Signal ground for speed reference input
Speed
Reference Input
Rotation Direction
Motor Speed
SGMMV Servomotor
+6 V
Forward
Rated motor speed
3000 min
-1
–3 V
Reverse
1/2 rated motor speed
–1500 min
-1
+1 V
Forward
1/6 rated motor speed
500 min
-1
SG
CN1
2
V-REF
1
D/A
0 V
Approx.
14 k
Ω
SERVOPACK
Host
controller
Analog