Note: Repeat the operations of steps 4 to 6 (phase-U and-V alternately) until adjusting the offset amounts both for phase-U
and -V in both directions cannot reduce the torque ripple any more.
Then, perform the same operation by adjusting by smaller amount.
7
Press the
Key to save the result of adjustment in
the SERVOPACK.
When the saving is completed, the status display
shows "DONE" for one second. The status display
then returns to show "RUN" again.
8
Press the
Key.
The display returns to the main menu of the utility
function.
Step
Display after Operation
Keys
Operation
R U N
M a n u a l O f f s e t
−
A D J
o f M o t o r C u r r e n t
Z A D J I U = - 0 0 0 1 9
Z A D J I V = - 0 0 0 1 6
R U N
−
F U N C T I O N
−
F n 0 0 F : C u r M a n u A d j
F n 0 1 0 : P r m P r o t e c t
F n 0 1 1 : M o t o r I n f o
F n 0 1 2 : S o f t V e r