beautypg.com

3 i/o signal allocations, 1 input signal allocations, 1) using factory settings – Yaskawa Σ-V Series AC Servo Drives Rotational Motor Analog Voltage Reference User Manual

Page 48

background image

3.3 I/O Signal Allocations

3-13

3

Wi

ring and

C

onne

ctio

n

3.3

I/O Signal Allocations

This section describes the I/O signal allocations.

3.3.1

Input Signal Allocations

In most cases, input signals can be used at the factory settings. Input signals can also be allocated as required.

(1) Using Factory Settings

Items in cells with bold lines in the following table are the factory-set signal allocations.

If the control method is changed in Pn000.1, the signals will function as required for the control method.

The factory-set signal allocations will remain unchanged.

When the control method is set to internal set speed control with a contact reference, i.e., when Pn000.1 is set
to 3, signal /P-CON (CN1-16) will function as /SPD-D, signal /P-CL (CN1-26) as /SPD-A, and signal /N-CL

(CN1-12) as /SPD-B.

Analog Voltage Reference (Model: SGDV-

ES1A)

Pulse Train Reference (Model: SGDV-

EP1A)

Pn000.1

Setting

Control Method Selection

CN1 Pin No.

15

16

17

18

25

26

12

0

Speed control

/S-ON

/P-CON

P-OT N-OT

/ALM-

RST

/P-CL

/N-CL

2

Torque control

3

Internal set speed control

Uses as

/SPD-D

Uses as

/SPD-A

Uses as

/SPD-B

4

Internal set speed control

Speed control

6

Internal set speed control

Torque control

9

Torque control

Speed control

Uses as
/C-SEL

Uses as

/P-CL

Uses as

/N-CL

A

Speed control

Speed control with zero

clamp function

Uses as

/ZCLAMP

Pn000.1

Setting

Control Method Selection

CN1 Pin No.

15

16

17

18

25

26

12

1

Position control

/S-ON

/P-CON

P-OT N-OT /ALM-

RST

/P-CL

/N-CL

3

Internal set speed control

Uses as

/SPD-D

Uses as

/SPD-A

Uses as

/SPD-B

5

Internal set speed control

Position con-

trol

B

Position control

Position control with

reference pulse inhibit function

Uses as

/INHIBIT

Uses as

/P-CL

Uses as

/N-CL