beautypg.com

5) i/o signal timing example, Analog – Yaskawa Σ-V Series AC Servo Drives Rotational Motor Analog Voltage Reference User Manual

Page 110

background image

5 Operation

5.4.1 Basic Settings for Position Control

5-30

(4) Electrical Specifications for Pulse Train Reference

Forms of pulse train references are as shown below.

Each multiplier’s maximum reference frequency before multiplication is 1 Mpps.

×

1 input pulse multiplier: 1 Mpps

×

2 input pulse multiplier: 1 Mpps

×

4 input pulse multiplier: 1 Mpps

(5) I/O Signal Timing Example

I/O signal timing example is as shown below.

Note: The interval from the time the servo ON signal is turned ON until a reference pulse is input must be at least 40 ms.

Otherwise the reference pulse may not be received by the SERVOPACK (t3).

Pulse Train Reference Form

Electrical Specifications

Remarks

Sign + pulse train input
(SIGN + PULS signal)
Maximum reference fre-
quency: 4 Mpps
(Maximum reference fre-
quency in case of open-
collector output: 200 kpps)

t1, t2, t3, t7

0.025

μ

s

t4, t5, t6

0.5

μ

s

τ

0.125

μ

s

T-

τ

0.125

μ

s

Sign (SIGN)

H = Forward
reference
L = Reverse
reference

CW + CCW pulse train
Maximum reference fre-
quency: 4 Mpps
(Maximum reference fre-
quency in case of open-
collector output: 200 kpps)

t1, t2

0.025

μ

s

t3

0.5

μ

s

τ

0.125

μ

s

T-

τ

0.125

μ

s

Two-phase pulse train with
90

°

phase differential

(phase A + phase B)
Maximum reference fre-
quency: 1 Mpps*
(Maximum reference fre-
quency in case of open-
collector output: 200 kpps)

t1

0.1

μ

s

t2

0.1

μ

s

τ

0.5

μ

s

T-

τ

0.5

μ

s

Reference pulse
form is set with
Pn200.0.

Forward reference

Reverse reference

t1 t2

t3

t4

t5

t6

t7

T

Ǽ

SIGN

PULS

t2

t3

T

Ǽ

CW

CCW

t1

Forward reference

Reverse reference

Phase B leads
phase A by 90

°

.

Phase B lags
phase A by 90

°

.

Phase A
Phase B

t2

Ǽ

T

t1

Forward reference

Reverse reference

Servo ON

Baseblock

Sign + pulse train

Release

t1

36 ms

t2

6 ms

(When Pn506 is set to 0.)
t3

40 ms

CN1-3

CN1-1

L

H

H

ON

t3

t2

t1

Analog