5 Operation

5.7.2 Switching Other Than Internal Set Speed Control (Pn000.1 = 9)

5-52

5.7.2

Switching Other Than Internal Set Speed Control (Pn000.1 = 9)

Use the following signals to switch control methods when Pn000.1 is set to 9. The control methods switch

depending on the signal status as shown below.

(1) Factory-set Input Signal Allocations (Pn50A.0 = 0)

(2) Changing Input Signal Allocations (Pn50A.0 = 1)

5.7.3

Switching Other Than Internal Set Speed Control (Pn000.1 = A or B)

Use the following signals to switch control methods when Pn000.1 is set to A or B. The control methods

switch depending on the signal status as shown below.

(1) Factory-set Input Signal Allocations (Pn50A.0 = 0)

(2) Changing Input Signal Allocations for Each Signal (Pn50A.0 = 1)

Type

Signal

Name

Connector

Pin Number

Setting

Control

Method

Input

/P-CON

CN1-16

ON (closed)

Speed

OFF (open)

Torque

Type

Signal

Name

Connector

Pin Number

Setting

Control

Method

Input

/C-SEL

Must be
allocated

ON (closed)

Speed

OFF (open)

Torque

Type

Signal

Name

Connector

Pin Number

Setting

Pn000.1 Setting and Control Method

n.

A

n.

B

Input

/P-CON

CN1-16

ON (closed)

Speed control with
zero clamp function

Position control with
reference pulse
inhibit function

OFF (open)

Speed

Position

Type

Signal

Name

Connector

Pin Number

Setting

Pn000.1 Setting and Control Method

n.

A

n.

B

Input

/ZCLAMP

Must be
allocated

ON (closed)

Speed control with
zero clamp function

OFF (open)

Speed

/INHIBIT

ON (closed)

Position control with
reference pulse
inhibit function

OFF (open)

Position