beautypg.com

4) output signal setting, 5) restriction – Yaskawa Σ-V Series AC Servo Drives Rotational Motor Analog Voltage Reference User Manual

Page 113

background image

5.4 Position Control (Pulse Train Reference)

5-33

5

Op

er

at

io

n

(4) Output Signal Setting

This output signal indicates when the multiplier of the input reference pulse has been switched for the Refer-
ence Pulse Input Multiplication Switching Input signal (/PSEL).

Note: Use parameter Pn510.2 to allocate the /PSELA signal for use. For details, refer to

3.3.2 Output Signal Allocations

.

(5) Restriction

When using the following utility functions, the reference pulse input multiplication switching function is dis-
abled.

Type

Signal

Name

Connector

Pin Number

Setting

Meaning

Output

/PSELA

Must be allocated

ON (closed)

The multiplier of the input reference pulse is enabled.

OFF (open)

The multiplier of the input reference pulse is disabled.

Parameter No.

Function

Fn004

Program JOG operation

Fn201