5 one-parameter tuning (fn203), 1 one-parameter tuning, 2 one-parameter tuning procedure – Yaskawa Σ-V Series AC Servo Drives Rotational Motor Analog Voltage Reference User Manual
Page 184: Caution

6.5 One-parameter Tuning (Fn203)
6-33
6
Adjustments
6.5
One-parameter Tuning (Fn203)
Adjustments with one-parameter tuning are described below.
6.5.1
One-parameter Tuning
One-parameter tuning is used to manually make tuning level adjustments during operation with a position ref-
erence or speed reference input from the host controller.
One-parameter tuning enables automatically setting related servo gain settings to balanced conditions by
adjusting one or two tuning levels.
One-parameter tuning performs the following adjustments.
• Gains (e.g., position loop gain and speed loop gain)
• Filters (torque reference filter and notch filter)
• Friction compensation
• Anti-resonance control
Refer to
6.5.4 Related Parameters
for parameters used for adjustments.
Perform one-parameter tuning if satisfactory response characteristics is not obtained with advanced autotun-
ing or advanced autotuning by reference.
To fine-tune each servo gain after one-parameter tuning, refer to
6.8 Additional Adjustment Function
.
Preparation
The following conditions must be met to perform one-parameter tuning.
The message “NO-OP” indicating that the settings are not appropriate will be displayed, if all of the following
conditions are not met.
• The test without a motor function must be disabled (Pn00C.0 = 0).
• The write prohibited setting parameter (Fn010) must be set to Write permitted (P.0000).
• The tuning-less function must be disabled (Pn170.0 = 0).
• The tuning mode must be set to 0 or 1 when performing speed control.
6.5.2
One-parameter Tuning Procedure
The following procedure is used for one-parameter tuning.
There are the following two operation procedures depending on the tuning mode being used.
• When the tuning mode is set to 0 or 1, the model following control will be disabled and one-parameter tun-
ing will be used as the tuning method for applications other than positioning.
• When the tuning mode is set to 2 or 3, the model following control will be enabled and it can be used for
tuning for positioning.
The digital operator or SigmaWin+ is required to execute this function.
Refer to the
Σ
-V Series User’s Manual, Operation of Digital Operator
(Manual No.: SIEP S800000 55) for
basic key operations of the digital operator.
CAUTION
• Vibration or overshooting may occur during adjustment. To ensure safety, perform one-parameter tuning in
a state where the SERVOPACK can come to an emergency stop at any time.