6.5 One-parameter Tuning (Fn203)

6-33

6

Adjustments

6.5

One-parameter Tuning (Fn203)

Adjustments with one-parameter tuning are described below.

6.5.1

One-parameter Tuning

One-parameter tuning is used to manually make tuning level adjustments during operation with a position ref-

erence or speed reference input from the host controller.

One-parameter tuning enables automatically setting related servo gain settings to balanced conditions by

adjusting one or two tuning levels.

One-parameter tuning performs the following adjustments.

• Gains (e.g., position loop gain and speed loop gain)
• Filters (torque reference filter and notch filter)
• Friction compensation
• Anti-resonance control

Refer to

6.5.4 Related Parameters

for parameters used for adjustments.

Perform one-parameter tuning if satisfactory response characteristics is not obtained with advanced autotun-

ing or advanced autotuning by reference.

To fine-tune each servo gain after one-parameter tuning, refer to

6.8 Additional Adjustment Function

.

Preparation

The following conditions must be met to perform one-parameter tuning.

The message “NO-OP” indicating that the settings are not appropriate will be displayed, if all of the following

conditions are not met.

• The test without a motor function must be disabled (Pn00C.0 = 0).
• The write prohibited setting parameter (Fn010) must be set to Write permitted (P.0000).
• The tuning-less function must be disabled (Pn170.0 = 0).
• The tuning mode must be set to 0 or 1 when performing speed control.

6.5.2

One-parameter Tuning Procedure

The following procedure is used for one-parameter tuning.

There are the following two operation procedures depending on the tuning mode being used.

• When the tuning mode is set to 0 or 1, the model following control will be disabled and one-parameter tun-

ing will be used as the tuning method for applications other than positioning.

• When the tuning mode is set to 2 or 3, the model following control will be enabled and it can be used for

tuning for positioning.

The digital operator or SigmaWin+ is required to execute this function.

Refer to the

Σ

-V Series User’s Manual, Operation of Digital Operator

(Manual No.: SIEP S800000 55) for

basic key operations of the digital operator.

CAUTION

• Vibration or overshooting may occur during adjustment. To ensure safety, perform one-parameter tuning in

a state where the SERVOPACK can come to an emergency stop at any time.