2 tuning-less levels setting (fn200) procedure, Caution, 1) preparation – Yaskawa Σ-V Series AC Servo Drives Rotational Motor Analog Voltage Reference User Manual

Page 164: 2) operating procedure

background image

6.2 Tuning-less Function

6-13

6

Adjustments

Load Level

a) Using the utility function

To change the setting, refer to

6.2.2 Tuning-less Levels Setting (Fn200) Procedure

.

b) Using the parameter

6.2.2

Tuning-less Levels Setting (Fn200) Procedure

The procedure to use the tuning-less function is given below.

The digital operator or SigmaWin+ is required to execute this function.

For the basic operation of the digital operator, refer to

Σ

-V Series User’s Manual, Operation of Digital Opera-

tor

(Manual No.: SIEP S800000 55).

(1) Preparation

The following conditions must be met to perform the tuning-less function. The message “NO-OP” indicating

that the settings are not appropriate will be displayed, if all of the following conditions are not met.

• The tuning-less function must be enabled (Pn170.0 = 1).
• The write prohibited setting parameter (Fn010) must be set to Write permitted (P.0000).
• The test without a motor function must be disabled. (Pn00C.0 = 0).

(2) Operating Procedure

Use the following procedure.

Load Level

Meaning

Mode 0

Load level : Low

Mode 1 [Factory setting]

Load level : Medium

Mode 2

Load level : High

Parameter

Meaning

When Enabled Classification

Pn170

n.0

Load level : Low (Mode 0)

Immediately

Setup

n.1

[Factory setting]

Load level : Medium (Mode 1)

n.2

Load level : High (Mode 2)

CAUTION

• To ensure safety, perform the tuning-less function in a state where the SERVOPACK can come to an

emergency stop at any time.

Step

Display after Operation

Keys

Operation

1

Press the

Key to view the main menu for the

utility function.
Use the

or

Key to move through the list,

select Fn200.

2

Press the

Key to display the load level of the

tuning-less mode setting screen.
Notes:

• If the response waveform causes overshooting or if

the load moment of inertia exceeds the allowable
level (i.e., outside the scope of product guarantee),
press the

Key and change the mode setting to

2.

• If a high-frequency noise is heard, press the

Key and change the mode setting to 0.