beautypg.com

Yaskawa Σ-V Series AC Servo Drives Rotational Motor Analog Voltage Reference User Manual

Page 290

background image

10 Appendix

10.2.2 Parameters

10-8

Pn007

2

Application Function Select
Switch 7

0000 to 005F

0000

Immediately

Setup

6.1.3

Pn008

2

Application Function Select
Switch 8

0000 to 7121

0000

After restart

Setup

(cont’d)

Parameter

No.

Size

Name

Setting

Range

Units

Factory

Setting

When

Enabled

Classification

Reference

Section

Analog Monitor 2 Signal Selection

00

Motor rotating speed (1 V / 1000 min

-1

)

01

Speed reference (1 V / 1000 min

-1

)

02

Torque reference (1 V/100% rated torque)

03

Position error (0.05 V/1 reference unit)

04

Position amplifier error (after electronic gears) (0.05 V/ 1 encoder pulse unit)

05

Position reference speed (1 V / 1000 min

-1

)

06

Reserved (Do not change.)

07

Reserved (Do not change.)

08

Positioning completion (positioning completed: 5 V, positioning not completed: 0 V)

09

Reserved (Do not change.)

0A

Torque feedforward (1 V/100% rated torque)

0B

Active gain (1st gain: 1 V, 2nd gain: 2 V)

0C

Completion of position reference (completed: 5 V not completed: 0 V)

0D

Reserved (Do not change.)

Reserved (Do not change.)

Reserved (Do not change.)

4th 3rd 2nd 1st

digit digit digit digit

n.

Lowered Battery Voltage Alarm/Warning Selection

Reference

Section

0

Outputs alarm (A.830) for lowered battery voltage.

5.9.3

1

Outputs warning (A.930) for lowered battery voltage.

Reserved (Do not change.)

Reserved (Do not change.)

Warning Detection Selection

Reference

Section

0

Detects warning.

9.2.1

1

Does not detect warning.

4th 3rd 2nd 1st

digit digit digit digit

n.