10.2 List of Parameters

10-25

10

Ap

pend

ix

Pn512

2

Output Signal Inverse Set-
ting

0000 to 0111

0000

After restart

Setup

3.3.2

Pn513

2

Output Signal Selection 4

0000 to 0333

0000

After restart

Setup

(cont’d)

Parameter

No.

Size

Name

Setting

Range

Units

Factory

Setting

When

Enabled

Classification

Reference

Section

Output Signal Inversion for CN1-7 Terminal

0

Does not inverse outputs.

1

Inverses outputs.

Output Signal Inversion for CN1-9 Terminal

0

Does not inverse outputs.

1

Inverses outputs.

Output Signal Inversion for CN1-10 Terminal

0

Does not inverse outputs.

1

Inverses outputs.

Reserved (Do not change.)

4th 3rd 2nd 1st

digit digit digit digit

n.

Reserved (Do not change.)

Reserved (Do not change.)

Reserved (Do not change.)

Reserved (Do not change.)

4th 3rd 2nd 1st

digit digit digit digit

n.