Magnum Energy ME-RTR Router User Manual
Page 85

Page 77
©
2014 Magnum Energy, Inc.
Using an AGS Module
Table 7-1, Software Differences Between AGS Versions
AGS Menu
(Button: Menu)
AGS Menu
Selections/Settings
ME-AGS-N
Required
CTRL: 03 Gen Control
OFF, ON, AUTO
≥ Vers 5.0
METER: 04 AGS Meters
04A AGS Status (Read Only)
≥ Vers 5.0
04B DC Volts to AGS (Read Only)
≥ Vers 5.0
04C Gen Run Time (Read Only)
≥ Vers 5.2
04D AGS Temp (Read Only)
≥ Vers 5.0
04E Since Run Days (Read Only)
≥ Vers 5.0
04F Since 100% Days (Read Only)
≥ Vers 5.3
04G Gen Hour Meter (Read Only)
≥ Vers 5.3
SETUP: 04 AGS Setup
04A Gen Run DC Volts
Start Volts = OFF, 9.0-15.9 (12V), 18.0-31.8
(24V), 36.0-63.6 (48V) VDC
≥ Vers 5.0
Stop Volts = 9.1-16.0 (12V), 18.2-32.0 (24V),
36.4-64.0 (48V), Float
Start/Stop Delay = 0-127 secs, 1-127 mins
04B Gen Run Time
OFF, Start Daily = 12:00AM – 11:45PM
≥ Vers 5.0
Stop Daily = 12:00AM – 11:45PM
04C Gen Run AC
Amps*
OFF, Start AC Amps = 5-60 Amps
≥ Vers 5.0
Stop AC Amps = 4-59 Amps
Start/Stop Delay = 0-127 secs, 1-127 mins
04D Gen Run SOC**
OFF, Start SOC = 20-99%
≥ Vers 5.0
Stop SOC = 21-100%
04E Gen Run Temp
OFF, Start Temp = Ext Input, 65-95F (18-35C)
≥ Vers 5.0
Run Time = 0.5-25.5 Hrs
04F Max Gen Run Time OFF, 0.1-25.5 Hrs
≥ Vers 5.2
04G Gen Quiet Time
OFF, Begin/End Quiet = 12:00AM-11:45PM
≥ Vers 5.0
OFF, Quiet Time Topoff = 30-120 mins
04H Gen Exercise
OFF, Start Gen Days = 1-255 Days
≥ Vers 5.0
Start Time = 12:00AM-11:45PM
Run Time = 0.1-25.5 Hrs
04I Gen No-Load Time Warm-up/Cooldown = 0-127 secs, 1-127 mins ≥ Vers 5.0
04J Gen 100% SOC
OFF, Start Gen Days = 1-255 Days
≥ Vers 5.0
Start Time = 12:00AM-11:45PM
TECH: 02 Port Vers (Read Only)
≥ Vers 5.0
TECH: 03 AccPort Vers (Read Only)
≥ Vers 5.0
TECH: 04 Fault History
AGS Faults
Fault LED = off; Fault status = view using
METER: 04A AGS Status menu
≥ Vers 5.0
Fault LED = blinking; Fault status = alternates
with inverter/charger status
* Only MS-PAE or MS-PE inverters ** Requires the ME-BMK (Battery Monitor)