Menu maps – Magnum Energy ME-RTR Router User Manual
Page 57

Page 49
©
2014 Magnum Energy, Inc.
Menu Maps
Figure 4-3, SETUP Button (System and Inverter Setup – ALL Ports) Menu Map
Celsius
Fahrenheit
OFF, 1-60 secs
01 System Setup
02 Inverter Setup
03 Charger Setup
ALL Select SETUP
SETUP
01A System Clock
12:52AM
ALL View SYS SETUP
01B Screen Setup
Contrast = 100%
Brightness = 50%
ALL View SYS SETUP
01C Power Save
PowerSave [Min] OFF
Port LEDs Auto
ALL View SYS SETUP
01D Temp Display
Fahrenheit
ALL View SYS SETUP
P
Hour = 12:52AM
Minute = 12:52AM
AM-PM = 12:52AM
12:00AM-11:59PM
PowerSave [Min]=
OFF, 1-60
01E Viewing Ports
Auto Scroll =
OFF
ALL View SYS SETUP
01F RTR Aux Relay
Open =20.0V/ 10secs
Close=28.0V/ 10secs
ALL View SYS SETUP
Port LEDs = Auto,
OFF
Delay= 0-127secs,
1-127mins
01 System Setup
02 Inverter Setup
03 Charger Setup
ALL Select SETUP
02A Search Watts
Sensitivity =
5 Watts
ALL View INV SETUP
02B Low Battery Cut
Out (LBCO) Volts =
20.0 Volts
ALL View INV SETUP
02C AC In - Time
Connect = 6:00AM
Disconnect = 6:00PM
ALL View INV SETUP
02D AC In – Volts DC
Connect = 22.0V
Disconnect = 28.2V
ALL View INV SETUP
P
OFF, 5-50 Watts
18.0-24.4 Volts (24v)
Connect & Disconnect
Time: 12:00AM-11:59PM
Conn = 18.0-32.0 (24v)
Discon = 18.2-32.0 (24v)
02G Inverter
Threshold to Start
Parallel = 60%
ALL View INV SETUP
02F Inverter Always
Power-Up When DC is
Connected = NO
ALL View INV SETUP
02E AC In – SOC
Connect = 80%
Disconnect = 100%
ALL View INV SETUP
OFF, 30%-90%
No, Yes
Connect= 20%-99%
Disconnect= 21%-100%
R
R
R
R
R
R
R
R
R
R
R
Contrast = 0-100%
Brightness = 0-100%
R
Open Volts = 16.0-34.0 (24v)
Close Volts = 16.0-34.0 (24v)
01G Aux Relay SOC
Open = 50%
Close= 100%
ALL View SYS SETUP
R
Open = 20-100%
Close = 20-100%