Magnum Energy ME-RTR Router User Manual
Page 30

©
2014 Magnum Energy, Inc.
Page 22
Setup
Port-specifi c Inverter METER Menus
The following METER menus are available for each port-connected inverter. Information is for the
specifi c selected inverter (versus ALL-Port meters that are system meter information).
METER: 01 DC Meters
• 01A DC Volts to Inverter: See information for 01A DC Volts to INV menu in previous section.
• 01B Inv/Chg DC Amps (In/Out of Battery): See information for 01B Inv/Chg DC Amps
menu in previous section.
METER: 02 AC Meters
• 02A
AC
Output: See information for 02A AC Output Volts and 02B AC Output Hz menus in
previous section.
• 02B AC Amps: See information for 02C System AC Amps menu in previous section.
• 02C Inv/Chg Amps (In/Out of Battery): See information for 02D Inv/Chg Sys Amps (In/
Out of Battery) menu in previous section.
• 02D AC Input Volts:
See information for 02H Input Volts AC1 menu in previous section.
Note: For a MSH-RE model inverters only, this menu also displays input volts for the AC2
source as well (02I Input Volts AC2). Refer to menu maps in Figure 4-2.
METER: 03 Timers
• 03A Charge Time: See information for 03A Charge Time menu in previous section.
03B Days Since: See information for 03B Days Since menu in previous section.
Figure 3-10, Accessing Port-specifi c METER Menus
Press &
hold 3
secs
METER
Press to
view meters
Inverting
25.6VDC 20ADC
ALL System Home
To access
System Home screen:
Press the PORT
button until the
device’s Port
screen displays
PORT
01 DC Meters
02 AC Meters
03 Timers
P1 Select INV METER
MS4024PAE Master
Inverting
25.6VDC 20ADC
P1 INV Home
METER
Figure 3-9, ALL Ports vs Port-specifi c METER Menus
02C System AC Amps:
AC Load = 20 AAC
AC Input = 30 AAC
ALL Read AC METER
02B AC Amps:
AC Load = 20 AAC
AC Input = 30 AAC
P1 Read AC METER
All Ports
Inverter Single Port
Identifies Port#
Note that menu
prefix & title
may differ
3.3.3.1
Additional METER Menus for Port-connected Inverters
The METER button also provides meter displays for each active port-connected inverter (or
accessory) in your system. These displays are similar to those listed in Section 3.3.3, but the
displayed information is specifi c to the particular inverter and/or model (Figures 3-9 & 3-10 below).