Magnum Energy ME-RTR Router User Manual
Page 126

Appendix B – Compatibility Matrix
Page 118
Button
FEATURES/SETTINGS
Model/
Level
Required
Default
Setting
Main Menu
Menu
Heading/Item
Selections/
Adjustments Range
METER
04 AGS
Meters
(cont.)
04D AGS Temp
Read Only display
≥Level 1
Read Only
04E Since Run Days
04F Since 100% Days
04G Gen Hour Meter
05 BMK
Meters
05A BMK SOC
Read Only display
≥Level 1
[6]
Read Only
05B DC Volts-BMK
05C DC Amps-BMK
05D Amp Hours In/Out
05E Resettable AHrs
05F Total kAHrs Out
05G Minimum VDC
05H Maximum VDC
05I Days Since 100%
SETUP
01 System
Setup
01A System Clock
Time = 12:00A-11:59P
≥Level 1
12:00A**
01B Screen Setup
Contrast = 0-100%
100%**
Brightness = 0-100%
50% **
01C Power Save
PowerSave= OFF, 1-60 min
15 Min
Port LEDs = Auto, OFF
Auto
01D Temp Display
Fahrenheit, Celsius
Fahrenheit
01E Viewing Ports
Auto Scroll = OFF, 1-60 sec
OFF
01F RTR Aux Relay
Open Volts = 8.0-17.0*
≥Level 1
10.0V
Close Volts = 8.0-17.0*
14.0V
Open Delay = 0-127 secs,
1-127 mins
10 secs
Close Delay = 0-127 secs,
1-127 mins
10 secs
01G Aux Relay SOC
Open = 20-100%
≥Level 4
[6]
50%
Close = 20-100%
100%
02 Invert
Setup
02A Search Watts
OFF, 5-50 Watts
≥Level 1
5 Watts
02B LBCO Setting
9.0-12.2* VDC
≥Level 2
10.0 VDC
02C AC In – Time
Connect=12:00A-11:45P
≥Level 3
[1]
6:00A
6:00P
Disconnect=12:00A-11:45P
02D AC In – Volts DC
Connect = 9.0-15.9*
≥Level 3
[1]
11.0V
Disconnect = 9.1-16.0*
14.1V
02E AC – In SOC
Connect = 20-99%
≥Level 3
[6]
80%
Disconnect = 21-100%
100%
02F Inv Always PowerUp NO, YES
≥Level 1
NO
02G Inverter Threshold
to Start Parallel
OFF, 30%-90%
MS-PAE,
MS-PE
60%