Appendix B – Compatibility Matrix
Appendix B – Router Feature to Inverter Compatibility
When the ME-RTR is released with new software, some of the features and functionality in the
router may not be available in an inverter or networked accessory that has an earlier software
level. In this case, the advanced setting is not recognized and will not function. Table B-1 lists the
ME-RTR features/settings and what inverter compatibility level is required (see the “Model/Level
Required” column).
1. Go to:
http://magnumenergy.com/inverter-compatibility/
to determine your inverter’s
compatibility level (L1, L2, L3, or L4).
2. Find the features/settings you want to use in Table B-1.
3. If your inverter compatibility level is ≥ the level required, your inverter supports the setting/feature.
4. If your inverter does not have the required compatibility level for a feature/setting you want,
contact Magnum Energy for a software upgrade.
Table B-1, ME-RTR (Version 3.1) Compatibility Matrix
Button
FEATURES/SETTINGS
Model/
Level
Required
Default
Setting
Main Menu
Menu
Heading/Item
Selections/
Adjustments Range
CTRL
01 AC In Control
Auto Connect
≥Level 1
Auto
Connect
VDC Connect, Time Con-
nect, AC In – Disabled
≥Level 3
[1]
SOC Connect
≥Level 3 [1]
[6]
02 Charger Control
Multi-Stage, Start
Float, Start Bulk
≥Level 4
Multi-Stage
03 Gen Control
OFF, ON, AUTO
≥Level 1 [7]
OFF**
04 RTR Aux Relay
Force Open, Force
Closed, Auto VDC,
Auto VDC (BTS Comp),
Auto Fault, Auto SOC
≥Level 1
Force Open
METER
01 DC Meters
01A DC Volts to Inv
Read Only display
≥Level 1
Read Only
01B Inv/Chg DC Amps
02 AC Meters
02A AC Output Volts
Read Only display
≥Level 4 [3]
Read Only
02B AC Output Hz
≥Level 4
02C System AC Amps
≥Level 4 [4]
02D Inv/Chg Sys Amps
≥Level 4 [4]
02E AC Load Amps
≥Level 4 [4]
02F AC Input Amps
≥Level 4 [4]
02G Inv/Chg AC Amps
≥Level 4 [4]
02H Input Volts AC1
MSH Models
02I Input Volts AC2
MSH-RE
03 Timers
03A Charge Time
Read Only display
≥Level 1
Read Only
03B Days Since
04 AGS
Meters
04A AGS Status
Read Only display
≥Level 1
Read Only
04B DC Volts to AGS
04C Gen Run Time