2014 Magnum Energy, Inc.

Troubleshooting

1. Press and hold the Power

ON/OFF pushbutton for 15

seconds.

2. Watch the Charging/

Inverting Status LED, after

approximately 15 seconds it

should come on and flash

rapidly to indicate the inverter

has reset. The Status LED will

go off after the pushbutton is

released.

Figure 6-1, Performing an Inverter Reset

6.3 Powering Down the Inverter

Note: The router is normally connected to multiple inverters. The procedure below should be

performed on all the inverters in the system (all at once) to ensure a complete system power-down.
To power-down the inverter:

1. Remove all AC power (utility or generator power) to the inverter.
2. Remove any accessories connected to the inverter and or/router.
3. Remove all DC power to the inverter (open all the inverter DC disconnects or disconnect the

positive battery cable to the inverter).

4. Remove the router from the inverter—ensure the router display is blank.
5. After all accessory devices have been disconnected from the inverter(s) and the inverters

have been disconnected from all power for 30 seconds, reconnect power to all inverters,

reconnect all accessory devices and the router, and resume operation.

Info: If DC disconnects are not used, there may be a momentary spark when the positive

battery cable is connected to the inverter’s terminal. This is normal and indicates that

the inverter’s internal capacitors are being charged.

6.2 Performing an Inverter Reset

Press and hold the Power ON/OFF button (see Figure 6-1) for approximately fi fteen (15) seconds

until the Charging/Inverting Status LED comes on and fl ashes. Once the fl ashing has begun, release

the Power ON/OFF button. The Charging/Inverting Status LED will go off after the button is released.

After the inverter reset is completed, press the Power ON/OFF button to turn the inverter ON.
Some older inverter models do not allow an inverter reset. If the inverter reset fails, you will need

to power-down the inverter using the procedure in Section 6.3 below. In either case, if an internal

fault does not clear, the inverter will require repair at a Magnum Energy Authorized Service Center.

Info: The Power ON/OFF button is a small momentary type switch which operates by

lightly pressing and releasing.

Info: All adjustable settings in the router (except SETUP: 01B Screen Setup, CTRL: 03

Gen Control and TECH: 07 Show all Menus—which revert back to default) are saved

in non-volatile memory and are preserved until changed—even if an inverter reset is

performed or if all power to the router or inverter is removed.